Features: `Dual Output LDO with Microcontroller Reset Monitor Functionality:-VOUT1= 1.5V to 3.3V @ 300mA-VOUT2= 1.5V to 3.3V @ 150mA-VRESET= 2.20V to 3.20V`Output Voltage andRESET Threshold Voltage Options Available (See Table8-1)`Low Dropout Voltage:-VOUT1= 104mV @ 300mA, Typical-VOUT2= 150mV @ 1...
TC1301A: Features: `Dual Output LDO with Microcontroller Reset Monitor Functionality:-VOUT1= 1.5V to 3.3V @ 300mA-VOUT2= 1.5V to 3.3V @ 150mA-VRESET= 2.20V to 3.20V`Output Voltage andRESET Threshold Voltage ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
`Dual Output LDO with Microcontroller Reset Monitor Functionality:
-VOUT1= 1.5V to 3.3V @ 300mA
-VOUT2= 1.5V to 3.3V @ 150mA
-VRESET= 2.20V to 3.20V
`Output Voltage andRESET Threshold Voltage Options Available (See Table8-1)
`Low Dropout Voltage:
-VOUT1= 104mV @ 300mA, Typical
-VOUT2= 150mV @ 150mA, Typical
`Low Supply Current: 116A, Typica TC1301A/B with both output voltages available
`Reference Bypass Input for Low-Noise Operation
`Both Output Voltages Stable with a Minimum of 1F Ceramic Output Capacito
`Separate Input forRESET Detect Voltage (TC1301A)
`Separate VOUT1and VOUT2SHDN pins(TC1301B)
`RESETOutput Duration: 300ms. Typical
`Power-Saving Shutdown Mode of Operation: 5.3s. Typica
`Wake-up from SHDN Small 8-pin DFN and MSOP Package Options
`Operating Junction Temperature Range:
--40 to +125
`Overtemperature and Overcurrent Protection
·Cellular/GSM/PHS Phones
·Battery-Operated Systems
·Hand-Held Medical Instruments
·Portable Computers/PDAs
·Linear Post-Regulators for SMPS
·Pagers
Absolute Maximum Ratings
VDD ..................................................................................6.5V
Maximum Voltage on Any Pin ............(VSS-0.3) to (VIN+ 0.3)V
Power Dissipation...........................Internally Limited (Note7)
Storage temperature.......................................-65 to +150
Maximum Junction Temperature, TJ...............................+150
Continuous Operating Temperature Range.....-40 to +125
ESD protection on all pins, HBM, MM........................ 4kV, 400V
Notice: Stresses above those listed under'Maximu Ratings'may cause permanent damage to the device. This in a stress rating only and functional operation of the device at those or any other conditions above those indicated in the operational listings of this specification is not implied. Exposure to maximum rating conditions for extended periods may affect device reliability.
Parameter Name | Value |
Max Input Voltage | 6 |
Typical Active Current (A) | 103 |
Typical Dropout Voltage @ Max. lout (mV) | 104 |
Typical Output Voltage Accuracy (%) | 0.5 |
Output Capacitor Type | Ceramic/Aluminum/Tantalum |