Features: ` Linearized Temperature-to-Voltage Converters` Direct Centigrade Output Voltage Scaling (TC03)` Wide Temperature Measurement Range (TC02) ............................... 20°C to +125` Excellent Temperature Converter Linearity .............................. 0.8Over Temperature` High Tem...
TC02: Features: ` Linearized Temperature-to-Voltage Converters` Direct Centigrade Output Voltage Scaling (TC03)` Wide Temperature Measurement Range (TC02) ............................... 20°C to +125` Ex...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
· Power Supply Thermal Shut-Down
· Temperature-Controlled Fans
· Temperature Measurement/Instrumentation
· Temperature Regulators
· Consumer Electronics
Supply Voltage ............................................................15V
Input Voltage, Any Terminal .............. 1.0 to (VCC +0.3V)
Operating Temperature (TC02)............. 20 to +125
Operating Temperature (TC03)............. 20 to +100
Storage Temperature ............................ 55 to +150
Lead Temperature (Soldering, 10 sec)
SOT-23B-3 ..................................................... +260
TO-92-3 .......................................................... +300
* Static-sensitive device. Unused devices must be stored in conductive material. Protect devices from static discharge and static fields. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to Absolute Maximum Rating Conditions for extended periods may affect device reliability.
The TC02/03 temperature sensors furnish a linearized output voltage directly proportional to measured temperature.
The TC03 has a temperature measurement range of 20 to +100. Its output voltage is directly calibrated in degrees Centigrade (i.e. VOUT = 10mV/ x Temperature ). An external pull-down resistor to a negative voltage source is required for temperature measurement below 0.
The TC02 has a temperature measurement range of 20 to +125, and operates with a single supply. It has the same output voltage slope with temperature as the TC03 (10mV/). The output voltage range is 300mV at 20 to 1,750mV at +125.
Small size, low cost and low power operation make the TC02/03 suitable for a wide range of general purpose temperature measurement applications.