Features: • Low reverse leakage current• Low power loss• High efficiency• Electrically isolated epoxy case for maximum heat dissipation• Case to terminal isolated voltage 2500V• RoHS compliantSpecifications Symbols Parameter TB5005 TB501 TB502...
TB5006: Features: • Low reverse leakage current• Low power loss• High efficiency• Electrically isolated epoxy case for maximum heat dissipation• Case to terminal isolated volta...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Symbols |
Parameter |
TB 5005 |
TB 501 |
TB 502 |
TB 504 |
TB 506 |
TB 508 |
TB 510 |
Unit |
Conditions |
VRRM |
Maximum Repetitive Peak Reverse Voltage |
50 |
100 |
200 |
400 |
600 |
800 |
1000 |
V |
|
VRMS |
Maximum RMS Voltage |
35 |
70 |
140 |
280 |
420 |
560 |
700 |
V |
|
VDC |
Maximum DC Blocking Voltage |
50 |
100 |
200 |
400 |
600 |
800 |
1000 |
V |
|
IF(AV) |
Maximum Average Forward Rectified Current |
50 |
A |
TA=60 | ||||||
IFSM |
Peak Forward Surge Current |
450 |
A |
8.3ms single half sine-wave superimposed on rated load (JEDEC Method) | ||||||
VF |
Maximum Instantaneous Forward Voltage Drop per leg |
1.1 |
V |
IF=25A | ||||||
IR |
Maximum DC Reverse Current at Rated DC Blocking Voltage per leg |
5.0 |
A |
TC=25 | ||||||
500 |
TC=125 | |||||||||
I²t |
Rating for Fusing (1ms<t<8.3ms) |
800 |
A²S |