PinoutSpecificationsDescriptionThe T-13617G is one kind of T1/CEPT/ISDN PRI interface transformer device (Reinforced Insulation Per EN 41003/EN 60950), T-13617G has some points of features:(1)Primary is Line Side; (2)Unbalanced current at TE: Idc = 1 mA max.; (3)Longitudinal Conversion Loss - 10KH...
T-13617G: PinoutSpecificationsDescriptionThe T-13617G is one kind of T1/CEPT/ISDN PRI interface transformer device (Reinforced Insulation Per EN 41003/EN 60950), T-13617G has some points of features:(1)Primar...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The T-13617G is one kind of T1/CEPT/ISDN PRI interface transformer device (Reinforced Insulation Per EN 41003/EN 60950), T-13617G has some points of features:(1)Primary is Line Side; (2)Unbalanced current at TE: Idc = 1 mA max.; (3)Longitudinal Conversion Loss - 10KHz to 300 KHz: 60 dB min. And materials used in the device of these units are UL94-VO and meet requirements of IEC 695-2-2 needle flame test. Parts shipped in anti-static trays. 40 pieces per tube.
The electrical characteristics of the T-13617G can be summarized as:(1)Open Circuit Inductance: 1.5 mHy;(2)Leakage Inductance: 0.70 uHy;(3)Interwinding Capacitance (CW/W): 30 pF;(4)Primary DC Resistance: 0.7 ohms;(5)Secondary DC Resistance: 0.9 ohms;(6)Isolation (HI-POT): 3000 VRMS. If you want to know more information about the T-13617G, please download the datasheet in www.seekic.com or www.chinaicmart.com .