Features: • Complies with Telcordia GR-1244-CORE, GR-253-CORE, and ITU-T G.812/G.813• Supports Master/Slave operation• Supports Free Run, locked, and Hold Over modes• Accepts 8 reference inputs and one cross reference each from 8 kHz to 77.76 MHz• Continuous input ref...
STC3800: Features: • Complies with Telcordia GR-1244-CORE, GR-253-CORE, and ITU-T G.812/G.813• Supports Master/Slave operation• Supports Free Run, locked, and Hold Over modes• Accepts...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
US $.86 - 1.53 / Piece
Battery Management Battery Monitor IC 32-Ram 12/14 ADC 8B
• Complies with Telcordia GR-1244-CORE, GR-253-CORE, and ITU-T G.812/G.813
• Supports Master/Slave operation
• Supports Free Run, locked, and Hold Over modes
• Accepts 8 reference inputs and one cross reference each from 8 kHz to 77.76 MHz
• Continuous input reference quality monitoring
• Input reference frequency are automatically detected
• Automatic or manual selection for active reference
• Supports hardwire pins to select active reference
• Four output signals: one selectable up to 155.52 MHz, one fixed at 8 kHz, one multi-frame sync fixed at 2 kHz, and 1.544 MHz or 2.048 MHz BITS output
• Output phase is adjustable in slave mode
• Frequency ramp control during reference switching
• Hit-less reference switching
• Better than 1 ppb Hold Over accuracy
• Configurable bandwidth filter for Stratum 3 or 3E
• Supports SPI and 8-bit parallel bus interface
• IEEE 1149.1 JTAG boundary scan
• Available in FBGA144 package
Symbol | Parameter | Minimum | Nominal | Maximum | Units | Notes |
Vdd2.5 | Logic power supply voltage, 2.5V | -0.3 | - | 3.0 | Volts | 1 |
Vdd3.3 | Logic power supply voltage 3.3V | -0.3 | - | 4.0 | Volts | 1 |
AVdd2.5 | Analog power supply voltage, 2.5V | -0.3 | - | 4.0 | Volts | 1 |
VIN | Logic input voltage, rel. to GND | -0.3 | - | Vdd3.3 + 0.5 | Volts | 1 |
TSTG | Storage Temperature | -55 | - | 110 | 1 |
Note 1: Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the evice. Exposure to absolute maximum rated conditions for extended periods may affect device reliability. Devices hould not be operated outside the Recommended Operating Conditions.
The STC3800 is an integrated single chip solution for the Synchronous Timing Source in SONET/SDH network elements. The device generates four synchronous clocks, including BITS, and is fully compliant with Telcordia GR-1244-CORE, GR-253-CORE and ITU-T G.812/G.813.
The STC3800 can operate in Free Run, locked or Hold Over mode. In the Free Run mode, it locks on an OCXO or TCXO. In the locked mode, it locks on one of 8 input reference clocks. The frequency of each input reference clock can be user selected or automatically detected by the device. The active reference can be automatically selected by the device based on a priority table or manually controlled by the user. All reference switches are hit-less. In Hold Over mode, the device generates outputs based on the frequency history of the last locked reference.
The STC3800 supports the Master or Slave mode of operation for redundant designs. In master mode, the device operates in Free Run, locked or Hold Over.
In slave mode, the output clocks are lockedto the master's primary Sync_Clk or 8 kHz synchronous clock output and are phase offset adjustable.
Parallel or serial bus interfaces are provided to access STC3800 internal control and status registers. Major operations can be performed from either the bus interface or external hardwire pins.