Features: ESD protection to IEC 61000-4-2, Level 4 Array of surge rated diodes with internal EPD TVS diode Protects two I/O lines Low capacitance (<10pF) for high-speed interfaces Low leakage current (< 1µA) Low operating voltage: 2.8V Solid-state technologyApplication 10/100 E...
SR2.8: Features: ESD protection to IEC 61000-4-2, Level 4 Array of surge rated diodes with internal EPD TVS diode Protects two I/O lines Low capacitance (<10pF) for high-speed interfaces Low lea...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
ESD protection to IEC 61000-4-2, Level 4
Array of surge rated diodes with internal EPD TVS diode
Protects two I/O lines
Low capacitance (<10pF) for high-speed interfaces
Low leakage current (< 1µA)
Low operating voltage: 2.8V
Solid-state technology
10/100 Ethernet
Firewire
Sensitive Analog Inputs
Video Line Protection
Portable Electronics
Microcontroller Input Protection
WAN/LAN Equipment
Rating |
Symbol |
Value |
Units |
Peak Pulse Power (tp = 8/20µs) |
Ppk |
200 |
Watts |
Peak Pulse Current (tp = 8/20µs) |
IPP |
14 |
A |
Peak Forward Voltage (IF = 1A, tp=8/20µs) |
VFP |
1.5 |
V |
Lead Soldering Temperature |
TL |
260 (10 sec.) |
°C |
Operating Temperature |
TJ |
-55 to +125 |
°C |
Storage Temperature |
TSTG |
-55 to +150 |
°C |
RailClamps are surge rated diode arrays designed to protect high speed data interfaces. The SR2.8 has been specifically designed to protect sensitive compo-nents which are connected to data and transmission lines from overvoltage caused by ESD (electrostaticdischarge), EFT (electrical fast transients), and tertiary lightning.
The unique design of the SR2.8 devices incorpo-rates four surge rated, low capacitance steering diodes and a TVS diode in a single package. The SR2.8 is constructed using Semtech's proprietary low voltage EPD technology for superior electrical characteristics at 2.8 volts.
During transient conditions, the SR2.8 direct the transient to either the positive side of the power supply line or to ground. The internal TVS diode pre-vents over-voltage on the power line, protecting any downstream components.
The SR2.8 allows the user to protect two high-speed data or transmission lines.The low inductance construction minimizes voltage overshoot during high current surges