Parameter |
Test condition |
Part |
Symbol |
Value |
Unit |
Maximum repetitive peak reverse voltage |
SL02 |
VRRM |
20 |
V | |
SL03 |
VRRM |
30 |
V | ||
SL04 |
VRRM |
40 |
V | ||
Maximum RMS voltage |
SL02 |
VRMS |
14 |
V | |
SL03 |
VRMS |
21 |
V | ||
SL04 |
VRMS |
28 |
V | ||
Maximum DC blocking voltage |
SL02 |
VDC |
20 |
V | |
SL03 |
VDC |
30 |
V | ||
SL04 |
VDC |
40 |
V | ||
Maximum average forward rectified current |
Ttp = 109 °C |
IF(AV) |
1.1 |
A | |
Peak forward surge current 8.3 ms single half sine-wave |
IFSM |
40 |
A |