Features: Green-Mode PWM Supports the Blue Angel Standard Low Start-up Current (5uA) Low Operating Current (2mA) Leading-Edge Blanking Constant Output Power Limit Universal Input Built-in Synchronized Slope Compensation Current Mode Operation Cycle-by-cycle Current Limiting Under Voltage Lockou...
SG6848: Features: Green-Mode PWM Supports the Blue Angel Standard Low Start-up Current (5uA) Low Operating Current (2mA) Leading-Edge Blanking Constant Output Power Limit Universal Input Built-in Synchro...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.

|
Parameter |
Unit |
Value |
Unit | |
|
DC Supply Voltage * Zener Clamp Zener Current |
VDD |
25 26 10 |
V V mA | |
|
Input Voltage to FB Pin |
VFB |
-0.3 to 6 V |
V | |
|
Input Voltage to Sense Pin |
VSense |
-0.3 to 6V |
V | |
|
Power Dissipation |
Pd |
300 |
mW | |
|
Operating Junction Temperature |
TJ |
150 |
||
|
Thermal Resistance (Junction to Air) |
SOT-26 |
RJA |
208.4 |
°C/W |
| DIP-8 |
82.5 |
mw | ||
|
Storage Temperature Range |
Tstg |
-55 to +150 |
°C | |
|
Lead Temperature (Soldering) |
20 sec SOT-26 |
TL |
220 260 |
°C |
| 10 sec DIP-8 | ||||
The SG6848 provides several special enhancements designed to meet the lowstandby-power needs of low-power SMPS. To minimize standby power consumption, the proprietary green-mode function provides off-time modulation to linearly decrease the switching frequency under light-load conditions. This green-mode function enables the power supply to easily meet even the strictest power conservation requirements.
The BiCMOS fabrication process of SG6848 enables reducing the start-up current to 5uA, and the operating current to 2mA. To further improve power conservation, a large start-up resistance can be used. Built-in synchronized slope compensation ensures the stability of peak current mode control. Proprietary internal compensation provides a constant output power limit over a universal AC input range (90VAC to 264VAC). Pulse-by-pulse current limiting ensures safe operation even during short-circuits.