Rectifiers 6.0 Amp 400V 35ns
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Product : | Ultra Fast Recovery Rectifiers | Configuration : | Single |
Reverse Voltage : | 400 V | Forward Voltage Drop : | 1.3 V |
Recovery Time : | 35 ns | Forward Continuous Current : | 6 A |
Max Surge Current : | 150 A | Reverse Current IR : | 5 uA |
Mounting Style : | Through Hole | Package / Case : | DO-201AD |
Packaging : | Reel |
Rating at 25ambient temperature unless otherwise specified.Single phase, half wave, 60 Hz, resistive or inductive load.For capacitive load, derate current by 20%
TYPE NUMBER |
SYMBOL |
SF 61G |
SF 62G |
SF 63G |
SF 64G |
SF 65G |
SF 66G |
SF 67G |
SF 68G |
UNITS |
Maximum Recurrent Peak Reverse Voltage |
VRRM |
50 |
100 |
150 |
200 |
300 |
400 |
500 |
600 |
V |
Maximum RMS Voltage |
VRMS |
35 |
70 |
105 |
140 |
210 |
280 |
350 |
420 |
V |
Maximum DC Blocking Voltage |
VDC |
50 |
100 |
150 |
200 |
300 |
400 |
500 |
600 |
V |
Maximum Average Forward Rectified |
I(AV) |
6.0 |
A | |||||||
Peak forward surge current, IFM (surge): 8.3mS single half sine-wave superimposed on rated load (MIL-STD-750D 4066 method) |
IFSM |
150 |
A | |||||||
Typical Thermal Resistance@6.0A |
VF |
0.975 |
1.3 |
1.7 |
V | |||||
Maximum DC Reverse Current @ TA=25 at Rated DC Blocking Voltage @ TA=125 |
IR |
5 |
uA | |||||||
Maximum Reverse Recovery Time (Note 1) |
Trr |
35 |
ns | |||||||
Typical Junction Capacitance (Note 2) |
CJ |
100
|
50 |
pF | ||||||
Typical Thermal Resistance |
RJA RJL |
40 5.0 |
/W | |||||||
Operating and Storage Temperature Range |
TJ,TSTG |
-65 to +150 |
Notes: 1. Reverse Recovery Test Conditions: IF=0.5A, IR=1.0A, IRR=0.25A
2. Measured at 1 MHz and Applied Reverse Voltage of 4.0 V D.C.