Application·Repetitive Peak Off−State Voltage : VDRM = 400, 600V Repetitive Peak Reverse Voltage : VRRM = 400, 600V·Average On−State Current : IT (AV) = 5A·Gate Trigger Current : IGT = 15mA (MAX.)Specifications CHARACTERISTIC SYMBOL RATING UNIT Repetitive Peak Off...
SF5G41A: Application·Repetitive Peak Off−State Voltage : VDRM = 400, 600V Repetitive Peak Reverse Voltage : VRRM = 400, 600V·Average On−State Current : IT (AV) = 5A·Gate Trigger Current : IGT = 1...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
CHARACTERISTIC |
SYMBOL |
RATING |
UNIT | |
Repetitive Peak Off−State Voltage and Repetitive Peak Reverse Voltage |
SF5G41A |
VDRM |
400 |
V |
SF5J41A |
600 | |||
Non−Repetitive Peak Reverse Voltage (Non−Repetitive < 5 ms, Tj = 0~125°C) |
SF5G41A |
VRSM |
500 |
V |
SF5J41A |
720 | |||
Average On−State Current (Half Sine Waveform TC=91°C) |
IT(AV) |
5 |
A | |
R.M.S On−State Current |
IT(RMS) |
7.8 |
A | |
Peak One Cycle Surge On−Stat Current (Non−Repetitive) |
ITSM |
80 (50 Hz) |
A | |
88 (60 Hz) | ||||
I2t Limit Value |
I2t |
32 |
A2s | |
Critical Rate of Rise of On−State Current |
di/dt |
100 |
A/s | |
Peak Gate Power Dissipation |
PGM |
5 |
W | |
Average Gate Power Dissipation |
PG(AV) |
0.5 |
W | |
Peak Forward Gate Voltage |
VFGM |
10 |
V | |
Peak Reverse Gate Voltage |
VRGM |
-5 |
V | |
Peak Forward Gate Current |
IGM |
2 |
A | |
Junction Temperature |
TJ |
-40to125 |
||
Storage Temperature Range |
Tstg |
-40to125 |