Features: • Implements two Utopia L3 Masters providing a solution to bridge Utopia Slave devices• Compliant with ATM-Forum af-phy-0136.000 (Utopia L3)• Meets 90MHz performance offering up to 1.4Gbps cell rate transfers• Single chip solution for improved system integration...
QLUM3316-PQ280C: Features: • Implements two Utopia L3 Masters providing a solution to bridge Utopia Slave devices• Compliant with ATM-Forum af-phy-0136.000 (Utopia L3)• Meets 90MHz performance offe...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Features: • Compliant with ATM-Forum af-phy-0039.000, June 1995 specification• Impleme...
Features: • Compliant with ATM-Forum af-phy-0039.000, June 1995 specification• Impleme...
Features: • Compliant with ATM-Forum af-phy-0039.000, June 1995 specification• Impleme...
The Utopia (Universal Test & Operations PHY Interface for ATM) interface QLUM3316-PQ280C is defined by the ATM Forum to provide a standard interface between ATM devices and ATM PHY or SAR (segmentation and Re-assembly) devices.
The Utopia Standard of QLUM3316-PQ280C defines a full duplex bus interface with a Master/Slave paradigm. The Slave interface responds to the requests from the Master. The Master performs PHY arbitration and initiates data transfers to and from the Slave device.
The ATM forum of QLUM3316-PQ280C has standardized the Utopia Levels 1 (L1) to 3 (L3). Each level extends the maximum supported interface speed from OC3, 155Mbps (L1) over OC12, 622Mbps (L2) to 3.2Gbit/s (L3).
The following Table 1 gives an overview of the main differences in these three levels.
Utopia Level 1 of QLUM3316-PQ280C implements an 8-bit interface running at up to 25MHz. Level 2 adds a 16 Bit interface and increases the speed to 50MHz. Level 3 extends the interface further by a 32 Bit word-size and speeds up to 104MHz providing rates up to 3.2 Gbit/s over the interface.
In addition to the differences in throughput, Utopia Level 2 of QLUM3316-PQ280C uses a shared bus offering to physically share a single interface bus between one master and up to 31 slave devices (Multi-PHY or MPHY operation). This allows the implementation of aggregation units that multiplex several slave devices to a single Master device. The Level 2 and Level 3 of QLUM3316-PQ280C are pointto- point only, whereas Level 1 has no notion of multiple slaves. Level 3 still has the notion of multiple slaves, but they must be implemented in a single physical device connected to the Utopia Interface.