Application·AC100~200V Active-Converter for PFC (Power Factor Correction), of Air-conditioner and soon.Specifications Symbol Parameter Conditions Ratings Unit Vi Supply Voltage Applied between : S-R 264 Vrms Vi(surge) Supply Voltage (surge) Applied between : ...
PS51277-A: Application·AC100~200V Active-Converter for PFC (Power Factor Correction), of Air-conditioner and soon.Specifications Symbol Parameter Conditions Ratings Unit Vi Supply Volt...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Symbol |
Parameter |
Conditions |
Ratings |
Unit |
Vi |
Supply Voltage | Applied between : S-R |
264 |
Vrms |
Vi(surge) |
Supply Voltage (surge) | Applied between : S-R, Surge value, Non-operating |
500 |
V |
VO |
Output Voltage | Applied between : P-N |
450 |
V |
VO(surge) |
Output Voltage (surge) | Applied between : P-N, Surge value, Non-operating |
500 |
V |
VCES |
Collector-Emitter Voltage |
- |
600 |
V |
VRRM |
Repetitive Peak Reverse Voltage |
- |
600 |
V |
Ii |
Input Current (100% Load) | TC +90°C, Vi = 200V, VO = 300V, fPWM = 20kHz |
15 |
Arms |
Ii(125%) |
Input Current (125% Load) | TC +90°C, Vi = 200V, VO = 300V, fPWM = 20kHz, 1 min Non-repetitive |
18.7 |
Arms |
I2t |
I2t for Fu sing | Value for 1msec of Surge Current |
75 |
A2s |
Tj |
Junction Temperature | (Note 1) |
20~+125 |
°C |