Solid State Relays Power Supply for Series LPCV 120 VAC
PS-120: Solid State Relays Power Supply for Series LPCV 120 VAC
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Product Type : | Industrial Mount |
MODEL |
PS-12012 |
PS-12014 |
PS-12018 | |
OUTPUT | DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER VOLTAGE ADJ . RANGE LINE R EGULATION LOAD REGULATION RIPPLE & NOISE (max.) VOLTAGE TOLERANCE |
12V 10A 0 ~ 10A 120W 80mVp-p 12 ~ 14V ±2.0% ±0.5% ±1.0% |
24V 5A 0 ~ 5A 120W 80mVp- 24 ~ 28V ±1.0% ±0.5% ±1.0% |
48V 2.5A 0 ~ 2.5A 120W 100mVp- 48 ~ 53V ±1.0% ±0.5% ±1.0% |
SETUP, R ISE, HOLD TIME |
500ms, 70ms, 30ms/230VAC 500ms, 70ms, 30ms/115VAC at full load | |||
INPUT | VOLTAGE RANGE |
88 ~ 132VAC/176 ~ 264VAC by switch 248 ~ 370VDC | ||
FREQUENCY RANGE |
47 ~ 63Hz | |||
EFFICIENCY (Typ.) |
80% |
84% |
85% | |
AC CURRENT |
2.6A / 115V AC 1.6A / 230V AC | |||
INRUSH CURRENT (max.) |
Cold Start 20A /115V AC 40A / 280V AC | |||
LEAKAGE CURRENT |
<3.5mA/ 240VAC | |||
PROTECTION | OVER LOAD |
105 ~ 150%rated output power | ||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||
OVER VOLTAGE |
15 ~ 16.5V |
29 ~ 33V |
58 ~ 65V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||
OVER TEMPERATURE |
85±5(TSW1) |
90±5(TSW1) |
90±5(TSW1) | |
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
Technical/Catalog Information | PS-120 |
Vendor | Crydom Co. |
Category | Relays |
Lead Free Status | Lead Free |
RoHS Status | RoHS Compliant |
Other Names | PS 120 PS120 |