Features: ·Plastic package has Underwriters LaboratoryFlammability Classification 94V-O utilizingFlame Retardant Epoxy Molding Compound·Glass passivated junction version of PG4001S thruPG4007S in A-405 package·1 ampere operation at TA=75·· with no thermal runaway·Exceeds environmental standards of...
PG4007S: Features: ·Plastic package has Underwriters LaboratoryFlammability Classification 94V-O utilizingFlame Retardant Epoxy Molding Compound·Glass passivated junction version of PG4001S thruPG4007S in A-...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
PG4001S | PG4002S | PG4003S | PG4004S | PG4005S | PG4006S | PG4007S | UNITS | |
Maximum Recurrent Peak Reverse Voltage | 50 | 100 | 200 | 400 | 600 | 800 | 1000 | V |
Maximum RMS Voltage | 35 | 70 | 140 | 280 | 420 | 560 | 700 | V |
Maximum DC Blocking Voltage | 50 | 100 | 200 | 400 | 600 | 800 | 1000 | V |
Maximum Forward Voltage at 1.0A | 1.1 | A | ||||||
Maximum Average Forward Rectified Current .375" lead length at TA=75·· |
1.0 | A | ||||||
Peak Forward Surge Current, IFM (surge): 8.3ms single half sine-wave superimposed on rated load(JEDEC method) |
30 | A | ||||||
Maximum Full Load Reverse Current, Full Cycle Average at TA=75 ·· |
30 | ··A | ||||||
Maximum DC Reverse Current at TA=25·· At Rated DC Blocking Voltage TA=100·· |
5.0 50 |
··A ··A | ||||||
Typical Junction capacitance (Note 1) | 15 | PF | ||||||
Typical Thermal Resistance R··JA(Note 2) | 50 | ··/W | ||||||
Operating and Storage Temperature Range | -55 to +150 | ·· |