Features: · COMBINED AC+DC CONVERTER FOR ISDN NT1+ APPLICATION· Uo INTERFACE (DC) AND MAIN (AC) INPUTS TO ENABLE NPM (Normal Power· Mode) AND RPM (Restricted Power Mode) CONDITIONS· INPUT FILTER TO MEET EMC REQUIREMENTS 5 INSULATED MAIN OUTPUTS· PEAK INPUT OVERVOLTAGE WITHSTANDING INPUT FUSE ON AC...
NT1+: Features: · COMBINED AC+DC CONVERTER FOR ISDN NT1+ APPLICATION· Uo INTERFACE (DC) AND MAIN (AC) INPUTS TO ENABLE NPM (Normal Power· Mode) AND RPM (Restricted Power Mode) CONDITIONS· INPUT FILTER TO ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The NT1+/INF2 Power Management Module is a comprehensive solution for ISDN-NT1 "Plus" (Network Termination Basic Access type Plus) equipment, combining both AC-DC and DC-DC functions. This version is suitable for Infineon ISDN U/S chip set.
The NT1+ Power Management Module (NT1+ PMM) provide the equipment with all necessary supply voltages as well as control signals to operate in the different operating modes, typically the Normal Power Mode (NPM) and the Restricted Power Mode (RPM).
Connected to the main, Input 1 is the AC input power to the NT1+ PMM, source of the whole necessary power in normal operating mode, namely in NPM. Input 2 is the DC power source when in RPM, therefore to connect to the U-Interface. When the main is available (230 Vac in this version) NT1+ PMM operate in Normal Power Mode, therefore it supply +40V (output 1) to the S-Interface being the output power 4.5 W. Output 2 delivers 5V (up to 720mW) for the logics and output 3 delivers -22V (up to 900 mW). Out voltage 4 is -50V with 100 mW output power. Last, output 5 delivers -130V and the output power can reach peaks of 700 mW.
When the main is missing, the module NT1+ remains active but only in Restricted Power Mode (RPM). The only power source in RPM is the Input 2, the U-Interface (Vi2). Therefore in RPM the following condition apply to outputs 1 and 2: output 1 reverses the voltage (it becomes -40V) and the maximum power Pout is reduced to 420 mW. P2max is reduced to 450 mW typically, however the output power available at outputs 2,3,4,5 mainly depend on input power available from the "U Interface" Vi2, therefore subject of variation as per local application and regulation.
In RPM NT1+ is also possible to set a different "emergency condition" setting HIGH the auxiliary input 3 (analog emergency input, Vin3). In this case Pout1 is reduced to 25mW, voltage level being -40V.
The following tables give you details of the various parameters in the 3 different operating modes of NT1+, namely NPM, RPM with Vi3 LOW, RPM with Vi3 HIGH.
NT1+'s Availability of the input AC main is also acknowledged by a specific auxiliary output (out 6, "EM signal"), a TTL-compatible signal set HIGH (to logic level "1") when the main is available and LOW when the AC main is missing.
The NT1+ presence of the "U" is optionally acknowledged by an other auxiliary output (out 7, RED LED) that is HIGH only when Vin2 > 40V.
The NT1+ PMM provides double insulation (3000 Vrms) between the inputs (1 and 2), and among the input 1 and all the outputs. Basic insulation exists among Out1 and all other outputs. The other outputs (including the 2 auxiliary outputs) and the input 3, share the same common ground. Double insulation (2000 Vrms) is provided among Input 2 (DC "U") and all outputs.
The NT1+ Power Management Module operate in the range -10 to +70 oC, storage temperatures in the range -40 to +85 oC are allowed.