Features: • Integrated Power Device• 100 V Operation• Thermal Limit Protection• Adjustable Current Limit• No External Current Shunt Required• Undervoltage and Overvoltage Lockouts• 6.5 A Continuous Operation• UIS RatedApplication• VoIP (Voice o...
NIS5101: Features: • Integrated Power Device• 100 V Operation• Thermal Limit Protection• Adjustable Current Limit• No External Current Shunt Required• Undervoltage and Ove...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Rating |
Symbol |
Value |
Unit |
Input Voltage, Operating (Input + to Input −) Transient (1 second) Steady−State |
Vin |
−0.3 to 110 −0.3 to 100 |
V |
Drain Voltage, Operating (Drain to Input −) Transient (1 second) Steady−State |
VDD |
−0.3 to 110 −0.3 to 100 |
V |
Drain Current, Continuous (TA = 25°C, 2.0 in2 Cu, double−sided board, 1 oz.) |
IDavg |
6.5 |
A |
Operating Temperature Range |
Tj |
−40 to 145 |
°C |
Non−Operating Temperature Range |
Tj |
−55 to 175 |
°C |
Lead Temperature, Soldering (10 Seconds) |
TL |
260 |
°C |
Drain Current, Peak (Internally Limited) |
Ipk |
20 |
A |
Thermal Resistance, Junction−to−Air 0.5 in2 copper 1.0 in2 copper |
RJA |
75 43 |
°C/W |
Power Dissipation @ TA = 25°C 0.5 in2 copper 1.0 in2 copper |
Pmax |
1.4 2.4 |
W |
ESD Immunity for Device Handling (All Pins) |
HBM JESD22−A114−B |
2.0 |
kV |
ESD Immunity Board Level (Note 1) |
IEC 61000−4−2 (Level 3) |
6.0 |
kV |
Lightning, Surge (8 x 20 sec) (Note 1) |
IEC 61000−4−5 (Level 3) |
2.0 |
kV |
48 |
A |