Features: • Quiescent Current of 0.5 µA Typical• High Accuracy Undervoltage Threshold of 2.0%• Wide Operating Voltage Range of 0.8 V to 10 V• Complementary or Open Drain Reset Output• Active Low or Active High Reset Output• Pb−Free Packages are Avail...
NCP300: Features: • Quiescent Current of 0.5 µA Typical• High Accuracy Undervoltage Threshold of 2.0%• Wide Operating Voltage Range of 0.8 V to 10 V• Complementary or Open Drai...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
US $.15 - .33 / Piece
Voltage Detectors / Monitors 0.9V Detector w/Reset High
Features: •Quiescent Current of 0.5 ATypinca•High Accuracy Undervoltage Threshold of 2...
Rating |
Symbol |
Value |
Unit |
Input Power Supply Voltage (Pin 2) |
Vin |
12 |
V |
Output Voltage (Pin 1)
Complementary, NCP300
N−Channel Open Drain, NCP30 |
VOUT
|
−0.3 to Vin +0.3 −0.3 to 12
|
V
|
Output Current (Pin 1) (Note 2) |
IOUT |
70 |
mA |
Thermal Resistance Junction−to−Air |
R_JA |
250 |
°C/W |
Operating Junction Temperature Range |
TJ |
−40 to +125 |
°C |
Operating Ambient Temperature Range |
TA |
−40 to +85 |
°C |
Storage Temperature Range |
Tstg |
−55 to +150 |
°C |
Moisture Sensitivity Level (TA = 235°C) |
MSL |
1 |
|
Latchup Performance
Positive
Negative |
ILATCHUP
|
200
200
|