Features: • Category 3 per EN 954-1• Stop category 0• 1 N.C. and 1 N.O. dual channel input• 2 N.O. safety outputs• 1 N.C. auxiliary output• Automatic reset• 45mm wide housingDescriptionThe MSR9T has 1 N.C. and 1 N.O. dual channel input for use with gate in...
MSR9T: Features: • Category 3 per EN 954-1• Stop category 0• 1 N.C. and 1 N.O. dual channel input• 2 N.O. safety outputs• 1 N.C. auxiliary output• Automatic reset•...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The MSR9T has 1 N.C. and 1 N.O. dual channel input for use with gate interlocks and emergency stop buttons in higher risk applications. The MSR9T is typically used for gate interlocks incorporating the diversity of one positive opening and one non positive opening interlock.
The MSR9T has output monitoring that can accommodate an automatic/manual reset. Automatic/manual reset can use a jumper or can be used to check operation of the contacts.
The MSR9T has 2 N.O. safety outputs and 1 N.C. auxiliary output. The safety outputs have independent and redundant internal contacts to help ensure the safety function. The auxiliary contact is an nonsafety output intended to provide an external signal about the status of the safety outputs.