Features: • Analog and pulse outputs• Optional watertight (NEMA 4X) enclosure• Optional displays for flow rate and totalization• Low cost• Excitation voltage for flow sensors• LED indication of pulse activityApplicationAnalog Output (rate)The Model UFT-1 analog ...
MODEL UFT-1: Features: • Analog and pulse outputs• Optional watertight (NEMA 4X) enclosure• Optional displays for flow rate and totalization• Low cost• Excitation voltage for flow s...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Features: • Military Grade• 0.25 0.5 GHz• In-Line Configuration• Connecto...
Features: • Small Size, Light Weight (2.8 grams)• Frequency Response to 5 KHz• R...
Analog Output (rate)
The Model UFT-1 analog transmitter converts a Data Industrial digital flow signal into a precalibrated 4-20 mA signal. It must be calibrated for each Data Industrial flow sensor installation. The pipe type, size, and maximum flow rate must be specified at the time of order if 4-20 mA output is to be used.
Pulse Output (totalization)
The Model UFT-1 pulse output divides the Data Industrial digital flow signal by a jumper-selectable 10 or 100 position to provide a more usable digital pulse. The pulse output is normally used where flow totalization is required. A simple conversion formula, using the flow factors for Data Industrial flow sensors on the next page, can convert the digital pulses to totalized gallons.
The pulse output is an optoisolated transistor switch that can be wired to source or sink pulses to totalizer equipment.
Note: This unit is not intended for field setup or field calibration.
The Model UFT-1 Universal Flow Transmitter is a solid-state, digital signal converter designed to operate with Data Industrial 200 Series flow sensors. Both analog (4-20 mA) and pulse outputs are available. The Model UFT-1 may be mounted in an optional NEMA 4X enclosure or with digital display of gpm or totalized flow (in a non-watertight enclosure).