Features: ` Overcharge detection voltage accuracy (0°C to 50°C) ±50 mV/cell.` Consumption current (Vcell=3.8V) 3A typ.` Consumption current (Vcell=2.3V) 0.3A typ.` Pin I/O current between cells (Vcell=3.8V) 0.3A max.` Delay time on overcharge voltage detection (Ct=0.22F) 1.5S typ.` Output current ...
MM1451: Features: ` Overcharge detection voltage accuracy (0°C to 50°C) ±50 mV/cell.` Consumption current (Vcell=3.8V) 3A typ.` Consumption current (Vcell=2.3V) 0.3A typ.` Pin I/O current between cells (Vce...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
` Overcharge detection voltage accuracy (0°C to 50°C) ±50 mV/cell.
` Consumption current (Vcell=3.8V) 3A typ.
` Consumption current (Vcell=2.3V) 0.3A typ.
` Pin I/O current between cells (Vcell=3.8V) 0.3A max.
` Delay time on overcharge voltage detection (Ct=0.22F) 1.5S typ.
` Output current (Vcell=VCC=4.5 V) 500A typ.
IC for double-protection of lithium-ion batteries with one to three cells.
Item |
Symbol |
Ratings |
Unit |
Operating temparature |
TOPR |
-20~+80 |
|
Storage temparature |
TSTG |
-40~+125 |
|
VCC Input voltage |
VCC |
-0.3~18 |
V |
V1 Input voltage *1 |
V1 | ||
V2 Input voltage *1 |
V2 | ||
V3 Input voltage *1 |
V3 | ||
Ct pin voltage *2 |
VCT |
-0.3~18 |
V |
VOUT pin voltage |
VOUT |
-0.3~18 |
V |
Allowable loss |
Pd |
170 |
mW |
Note 1 : *1 18V V3 V2 V1-0.3
Note 2 : *2 Do not impress current of 300A or more on the Ct pin.