Features: • Speed-Up Sampling Rate of 40 ms of Internal Clock Period (Pin 12) After First Detection of Smoke• Timer Function for Reduced Sensitivity for a Nominal Period of 6.43 Minutes (10 Minutes Max)• High-Smoke Detection in the Reduced Sensitivity Mode• Internal and E...
MC14568: Features: • Speed-Up Sampling Rate of 40 ms of Internal Clock Period (Pin 12) After First Detection of Smoke• Timer Function for Reduced Sensitivity for a Nominal Period of 6.43 Minutes ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Rating |
Symbol |
Value |
Unit |
Supply Voltage Range |
VDD |
-0.5 to +15 |
V |
Input Voltage Range |
VIN |
-0.3 to VDD +0.3 |
V |
Maximum Current (Source/Sink) by Pins 6 (VDD) and Pin 9 (VSS) |
IDS |
30 |
mA |
Maximum Current Input Pins |
IIN |
±10 |
mA |
Maximum Current Output Pins (Pins 2, 4, 5, 10, 11) |
- |
±25 |
mA |
Maximum Current (Pin 15) |
- |
±1.0 |
mA |
Operating Temperature Range |
TA |
0 to +50 |
°C |
Storage Temperature Range |
TSTG |
-55 to +125 |
°C |
Human Body Model ESD Rating |
VESD |
1000 |
V |
The MC14568, when used with an ionization chamber and a small number of external components, will detect smoke. When smoke is sensed, an alarm is sounded via an external piezoelectric transducer and internal drivers. MC14568 is designed to operate in smoke detector systems that comply with UL217 and UL268 specifications.
An internal oscillator with associated logic controls the overall functionality by powering down the MC14568 for 1.67 seconds and sensing smoke in a 10 ms window. In this way, standby current consumption is reduced to between 5.0 and 9.0 µA, thus providing longer battery life. In addition, a networking capability allows as many as 125 to be interconnected so that if any unit senses smoke, all units will sound an alarm.
The MC14568 is supplied in a 16-pin dual in-line plastic package and is designed to run on a power supply between 6 to 12 Volts.