Features: ` No Power-Supply Sequencing Required` Rail-to-Rail Signal Handling` All Switches Off with Power Off` All Switches Off when V+ is Off and V- is On` ±40V Fault Protection with Power Off` ±36V Fault Protection with ±15V Supplies` Control Line Fault Protection from V- - 0.3V to V- + 40V` Pi...
MAX313F: Features: ` No Power-Supply Sequencing Required` Rail-to-Rail Signal Handling` All Switches Off with Power Off` All Switches Off when V+ is Off and V- is On` ±40V Fault Protection with Power Off` ±3...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
(Voltages Referenced to GND.)
V+...........................................................................-0.3V to +44V
V- ...........................................................................-44V to +0.3V
V+ to V-..................................................................-0.3V to +44V
IN_ ......................................................... (V- - 0.3V) to (V- + 40V)
NO_, NC_ to COM_ (Note 1) .................................. -40V to +40V
COM_, NO_, NC_ Voltage with
Power On (Note 1)................................................. -36V to +36V
COM_, NO_, NC_ Voltage with
Power Off (Note 1)................................................. -40V to +40V
Peak Current COM_, NO_, NC_
(pulsed at 1ms, 10% duty cycle) ...................................±300mA
Continuous Current (any other terminal)........................ ±30mA
Continuous Current (COM_, NO_, NC_)..........................±100mA
Continuous Power Dissipation (TA = +70°C)
16-Pin SO (derate 8.7mW/°C above +70°C).................696mW
16-Pin Plastic DIP (derate 10.53mW/°C
above +70°C) .............................................................. 842mW
Operating Temperature Range ...................... -40°C to +85°C
Junction Temperature .................................................. +150°C
Storage Temperature Range ........................ -65°C to +160°C
Lead Temperature (soldering, 10s) .............................. +300°C
Note 1: COM_, NO_, and NC_ pins are fault protected. Signals on COM_, NO_, and NC_ exceeding -36V to +36V may damage the device during power-on conditions. When the power is off, the maximum range is -40V to +40V.
Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
The MAX312F/MAX313F/MAX314F are quad, singlepole/ single-throw (SPST), fault-protected analog switches. They are pin compatible with the industry-standard nonprotected MAX312/MAX313/MAX314. These switches feature fault-protected inputs and Rail-to-Rail signalhandling capability. All analog signal terminals are protected from overvoltage faults up to ±36V with power on and up to ±40V with power off. During a fault condition, the COM_, NO_, or NC_ terminal becomes an open circuit and only microamperes of leakage current flow from the source. On-resistance is 10 (max) and is matched between switches to 0.5 (max) at +25°C.
The MAX312F has four normally closed (NC) switches. The MAX313F has four normally open (NO) switches. The MAX314F has two NC and two NO switches. These MAX312F/MAX313F/MAX314F CMOS switches operate with dual power supplies ranging from ±4.5V to ±20V or a single supply between +9V and +36V. All digital inputs have +0.8V and +2.4V logic thresholds, ensuring both TTL and CMOS logic compatibility when using ±15V or a single +12V supply.
For supply voltages of ±5V, +5V, and +3V, refer to the MAX4711/MAX4712/MAX4713 data sheet