Features: ±80V Fault ProtectionThree Operating Modes High-Speed Operation up to 2Mbps Slope Control Mode to Reduce EMI (40kbps to 500kbps)15A Low-Current Shutdown ModeAutoshutdown when Device Is InactiveAutomatic Wakeup from ShutdownThermal ShutdownCurrent LimitingFully Compatible with the ISO 118...
MAX3053: Features: ±80V Fault ProtectionThree Operating Modes High-Speed Operation up to 2Mbps Slope Control Mode to Reduce EMI (40kbps to 500kbps)15A Low-Current Shutdown ModeAutoshutdown when Device Is Ina...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
±80V Fault Protection
Three Operating Modes High-Speed Operation up to 2Mbps Slope Control Mode to Reduce EMI (40kbps to 500kbps)
15A Low-Current Shutdown Mode
Autoshutdown when Device Is Inactive
Automatic Wakeup from Shutdown
Thermal Shutdown
Current Limiting
Fully Compatible with the ISO 11898 Standard
Industrial Control and Networks Printers Automotive Systems HVAC Controls Telecom 72V Systems
VCC to GND ............................................................ ..............-0.3V to +6V
TXD, RS, RXD, SHDN to GND.....................................-0.3V to (VCC + 0.3V)
RXD Shorted to GND................................................. ..............Continuous
CANH, CANL to GND...........................................-80V to +80V Continuous
Continuous Power Dissipation
8-Pin SO (derate 5.9mW/°C above +70°C) ................................470mW
Operating Temperature Ranges
MAX3053ASA ................................................................-40°C to +125°C
MAX3053ESA ..................................................................-40°C to +85°C
Junction Temperature...................................................................+150°C
Storage Temperature Range ........................................-65°C to +150°C
Lead Temperature (soldering, 10s) ...............................................+300°C
The MAX3053 interfaces between the control area network (CAN) protocol controller and the physical wires of the bus lines in a CAN. It is primarily intended for industrial systems requiring data rates up to 2Mbps and features ±80V fault protection against shorts to high-voltage power buses. The device provides differential transmit capability to the bus and differential receive capability to the CAN controller.
The MAX3053 has three different modes of operation: high-speed, slope control, and shutdown. High-speed mode allows data rates up to 2Mbps. In slope control mode, data rates are between 40kbps and 500kbps so the effects of EMI are reduced and unshielded twisted or parallel cable may be used. In shutdown mode, the transmitter is switched off, and the receiver is switched to a low-current mode.
An autoshutdown function puts the device in 15A shutdown mode when the bus or CAN controller is inactive for 47ms or greater.The MAX3053 is available in an 8-pin SO package and is specified for -40°C to +125°C operation.