Features: ` Accurate Current Limit (0.7A min, 1.0A max)` Guaranteed 0.75A Short-Circuit Protection` 10ms Internal Fault-Blanking Timeout` No Fault Signal During Power-Up` LatchedFAULT Output Turns Off Power Switch (MAX1694)` Thermal Shutdown Protection` 2.7V to 5.5V Supply Range` 14A Supply Curren...
MAX1693H: Features: ` Accurate Current Limit (0.7A min, 1.0A max)` Guaranteed 0.75A Short-Circuit Protection` 10ms Internal Fault-Blanking Timeout` No Fault Signal During Power-Up` LatchedFAULT Output Turns O...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
IN, ON (ON),FAULT to GND.......................................-0.3V to +6V
OUT to GND ................................................-0.3V to (VIN + 0.3V)
Maximum Continuous Switch Current .....1.2A (internally limited)
OUT Short Circuit to GND ..........................................Continuous
Continuous Power Dissipation (TA = +70°C)
10-Pin MAX (derate 5.6mW/°C above +70°C) ...........444mW
Operating Temperature Range
MAX1693EUB/MAX1693HEUB/
MAX1694EUB .................................................-40°C to +85°C
Storage Temperature Range ........................-65°C to +150°C
Lead Temperature (soldering, 10s) ..............................+300°C
Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
The MAX1693/(MAX1693H)/MAX1694 are current-limited, 60m switches with built-in fault blanking. Their accurate preset current limit of 0.7A to 1.0A makes them ideally suited for USB applications. Their low quiescent supply current (14A) and shutdown current (1A) conserve battery power in portable applications. The MAX1693/(MAX1693H)/MAX1694 operate with inputs from 2.7V to 5.5V, making them ideal for both 3V and 5V systems.
A fault signal notifies the microprocessor that the internal current limit has been reached. A 10ms fault-blanking feature allows momentary faults (such as those caused when hot-swapping into a capacitive load) to be ignored, thus preventing false alarms to the host system. This fault blanking also prevents a fault signal from being issued when the device is powering up.
In the MAX1693/(MAX1693H), an output overcurrent condition causes the switch to current limit at 0.7A to 1.0A and FAULT to go low after the 10ms blanking period. When the overcurrent condition is removed, FAULT returns to its high-impedance state. In the MAX1694, any overcurrent longer than 10ms will latch the switch open and set FAULT low. The latch is cleared by cycling the ON input or by powering up the device again. This feature saves power by preventing the device from thermally cycling on and off in case of a persistent short-circuit condition.
The MAX1693/(MAX1693H)/MAX1694 have several safety features to ensure that the USB port is protected. Built-in thermal-overload protection limits power dissipation and junction temperatures. All devices have accurate internal current-limiting circuitry to protect the input supply against overload. They are available in space-saving 10-pin MAX packages.