Features: ` Number of effective pixels : 512 (H) x 492 (V)` Number of optical black pixels -Horizontal : 2 front and 28 rear` Pixel pitch : 9.6 µm (H) x 7.5 µm (V)` Mg, G, Cy, and Ye complementary color filters (For LZ2315A)` Low fixed-pattern noise and lag` No burn-in and no image dis...
LZ2316AR: Features: ` Number of effective pixels : 512 (H) x 492 (V)` Number of optical black pixels -Horizontal : 2 front and 28 rear` Pixel pitch : 9.6 µm (H) x 7.5 µm (V)` Mg, G, Cy, and Ye com...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
PARAMETER |
SYMBOL |
RATING |
UNIT |
NOTE |
Output transistor drain voltage |
VOD |
0 to +15 |
V |
|
Reset gate clock voltage |
VRD |
0 to +15 |
V |
|
Overflow drain voltage |
VOFD |
Internal output |
V |
1 |
Test pin, T1 |
VT1 |
0 to +15 |
V |
|
Reset gate clock voltage |
VRS |
Internal output |
V |
2 |
Vertical shift register clock voltage |
VV |
0 to 7.5 |
V |
|
Horizontal shift register clock voltage |
VH |
-0.3 to +7.5 |
V |
|
Transfer gate clock voltage |
VTG |
-0.3 to +15 |
||
Storage temperature |
TSTG |
-40 to +85 |
||
Ambient operating temperature |
TOPR |
-20 to +70 |
NOTES :
1. Do not connect to DC voltage directly. When OFD is connected to GND, connect VOD to GND. Overflow drain clock is applied below 13 Vp-p.
2. Do not connect to DC voltage directly. When RS is connected to GND, connect VOD to GND. Reset gate clock is applied below 8 Vp-p.
The LZ2315A/LZ2316AR are 1/3-type (6.0 mm) solid-state image sensors that consist of PN photodiodes and CCDs (charge-coupled devices) driven by dual-power-supply. With approximately 270 000 pixels (542 horizontal x 492 vertical), the sensor provides a stable high-resolution color (LZ2315A)/B/W (LZ2316AR) normal or mirror image.