PinoutSpecificationsSupply voltage, VCC+ (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..... 22 VSupply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....22 VDifferential input voltage (see Note 2) . ....
LT1013A: PinoutSpecificationsSupply voltage, VCC+ (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..... 22 VSupply voltage, VCC (see Note 1) . . . . . . . . . . . . ....
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Supply voltage, VCC+ (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..... 22 V
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....22 V
Differential input voltage (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ......±30 V
Input voltage range, VI (any input, see Note 1) . . . . . . . . . . . . . . . . . .....VCC5 V to VCC+
Duration of short-circuit current at (or below) 25(see Note 3) . . . . . . . . . . . . . ......unlimited
Operating free-air temperature range, TA: LT1013C, LT1013AC, LT1013D . . . .....0 to 70
LT1013I, LT1013AI, LT1013DI . . .....40to 105
LT1013M, LT1013AM, LT1013DM . ...55 to 125
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65to 150
Lead temperature 1.6 mm (1/16 inch) from case for 10 seconds: D or P package . . . . . . .260
Case temperature for 60 seconds: FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
Lead temperature 1.6 mm (1/16 inch) from case for 10 seconds: JG package . . . . . . . . . . 300
The LT1013 is a dual precision operational amplifier featuring low offset voltage temperature coefficient, high gain, low supply current, and low noise.
The LT1013 can be operated from a single 5-V power supply; the common-mode input voltage range includes ground, and the output can also swing to within a few millivolts of ground.
Crossover distortion is eliminated. The LT1013 can be operated with both dual ±15-V and single 5-V supplies.
The LT1013C and LT1013AC, and LT1013D are characterized for operation from 0to 70. The LT1013I and LT1013AI, and LT1013DI are characterized for operation from 40 to 105. The LT1013M and LT1013AM, and LT1013DM are characterized for operation over the full military temperature range of 55to 125.