Features: · Ultra low dropout voltage· Low ground pin current· 0.04% load regulation· The guaranteed output current is 1A DC· Output voltage accuracy ± 1.5%· ERROR flag indicates output status· Low output capacitor required· Overtemperature protection and overcurrent protectionSpecifications ...
LR1108: Features: · Ultra low dropout voltage· Low ground pin current· 0.04% load regulation· The guaranteed output current is 1A DC· Output voltage accuracy ± 1.5%· ERROR flag indicates output status· Low ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Features: *Low dropout voltage (1V Typ.)*2.85V device performances are suitable for SCSI-2 active ...
PARAMETER | SYMBOL | RATINGS | UNIT |
Input Voltage (Operating), (Note 10) | VIN | 2.5~7.0 | V |
Input Voltage (Survival) | -0.3~+7.5 | V | |
Shutdown Input Voltage | VIN(SHDN) | -0.3~VIN+0.3 | V |
Output Voltage (Survival), (Note 4), (Note 5) | VOUT | -0.3~+7.5 | V |
IOUT (Survival) | Short Circuit Protected | ||
Maximum Voltage for ERROR Pin | VIN+0.3 | V | |
Maximum Operating Current (DC) | 1 | A | |
Power Dissipation (Note 2) | PD | Internally Limited | |
Junction Temperature | TJ | +125 | |
Operating Temperature | TOPR | -40~+125 | |
Storage Temperature | TSTG | -65~+150 |
The UTC LR1108 operate from a +2.5V ~ +7.0V input supply as fast ultra low-dropout linear regulators. Wide output voltage range options are available. The fast response characteristic to make UTC LR1108 suitable for low voltage microprocessor application. The low quiescent current operation and low dropout quality caused by the CMOS process.
The UTC LR1108 has ultra low dropout voltage; 300mV at 600mA load current typically.
The ground pin current is typically 200uA at 1mA load current. ERROR Flag: When the output voltage drops 10% below nominal value Error flag goes low.
Output Voltage Precision: Multiple output voltage options are available and ranging from 1.2V ~ 5.0V at room temperature with a guaranteed accuracy of ±1.5%, and ±3.0% when varying line, load and temperature.