Features: Wide Range of Supply Voltages: Single Supply...3 V to 30 V (LM2904 and LM2904Q...3 V to 26 V) or Dual Supplies Low Supply-Current Drain Independent of Supply Voltage . . . 0.7 mA Typ Common-Mode Input Voltage Range Includes Ground, Allowing Direct Sensing Near Ground Low Input Bias and...
LM358A: Features: Wide Range of Supply Voltages: Single Supply...3 V to 30 V (LM2904 and LM2904Q...3 V to 26 V) or Dual Supplies Low Supply-Current Drain Independent of Supply Voltage . . . 0.7 mA Typ Com...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
LM158, LM158A LM258, LM258A LM358, LM358A |
LM2904 LM2904Q |
UNIT | ||
Supply voltage, VCC (see Note 1) |
32 | 26 | V | |
Differential input voltage, VID (see Note 2) |
32 ± |
26 ± |
V | |
Input voltage, VI (either input) |
0.3 to 32 | 0.3 to 26 | V | |
Duration of output short circuit (one amplifier) to ground at (or below) 25 free-air temperature (V 15 V) (see Note 3) |
Unlimited | Unlimited | ||
Continuous total power dissipation | See Dissipation Rating Table | |||
Operating free-air temperat rature range, TA |
LM158, LM158A | 55 to 125 | ||
LM258, LM258A | 25 to 85 | |||
LM358, LM358A | 0 to 70 | |||
LM2904, LM2904Q | 40 to 125 | |||
Storage temperature range, Tstg |
65 to 150 | 65 to 150 | ||
Case temperature for 60 seconds | FK package | 260 | ||
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds | JG package | 300 | 300 | |
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds | D, P, or PW package | 260 | 260 |
These LM358A consist of two independent, high-gain, frequency-compensated operational amplifiers designed to operate from a single supply over a wide range of voltages. Operation from split supplies also is possible if the difference between the two supplies is 3 V to 30 V (3 V to 26 V for the LM2904 and LM2904Q), and VCC is at least 1.5 V more positive than the input common-mode voltage. The low supply-current drain is independent of the magnitude of the supply voltage.
Applications include transducer amplifiers, dc amplification blocks, and all the conventional operational amplifier circuits that now can be more easily implemented in single-supply-voltage systems. For example, these devices can be operated directly from the standard 5-V supply used in digital systems and easily provides the required interface electronics without additional ±5-V supplies.
The LM358A is manufactured to demanding automotive requirements.
The LM358A and LM158A are characterized for operation over the full military temperature range of 55 to 125.The LM258 and LM258A are characterized for operation from 25 to 85, the LM358 and LM358A from 0 to 70, and the LM2904 and LM2904Q from 40 to 125.