Solid State Relays Normally Open/Closed Form 1A/1B/1C 350V
LH1502BACTR: Solid State Relays Normally Open/Closed Form 1A/1B/1C 350V
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Product Type : | PCB Mount | Mounting Style : | SMD/SMT |
Load Voltage Rating : | 350 V | Load Current Rating : | 0.15 A |
Contact Form : | 1 Form A (SPST-NO), 1 Form B (SPST-NC) | Output Device : | MOSFET |
Package / Case : | SMD-8 |
TA=25
Stresses in excess of the Absolute Maximum Ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of the data sheet. Exposure to maximum rating conditions for extended periods can adversely affect device reliability.
Ambient Operating Temperature Range,TA..................40 to +85
Storage Temperature Range,Tstg.............................. 40 to +125
Pin Soldering Temperature, t=10 s max,TS.............................. 260
Input/Output Isolation Test Voltage,
t=1.0 s,IISO=10A max.,VISO.........................................3750 VRMS
Pole-to-Pole Isolation Voltage (S1 to S2)*
(dry air, dust free, at sea level) ...........................................1600 V
LED Continuous Forward Current,IF.........................................50 mA
LED Reverse Voltage,IR10A,VR............................................ 8.0 V
dc or Peak ac Load Voltage,IL50A,VL.................................. 350 V
Continuous dc Load Current,IL
(Form C Operation) .............................................................150 mA
Peak Load Current,IP
(t=100 ms) Form A ........................................................................ †
(single shot) Form B ............................................................ 350 mA
Output Power Dissipation (continuous),PDISS.......................600 mW
* Breakdown occurs between the output pins external to the package.
† Refer to Current Limit Performance Application Note for a discussion on relay operation during transient currents.
The LH1502BACTR relays contain normally open and normally closed switches that can be used independently as a 1 Form A and 1 Form B relay, or when used together, as a 1 Form C relay. The relays are constructed as a mult.- chip hybrid device. Actuation contral is via an Infrared LED. The output switch is a combination of a photodiode array with MOSFET switches and control circuity.