PinoutSpecifications Symbol Parameter Value Unit VCC DC Supply Voltage (Referenced to GND) -0.5 to +20 V VIN DC Input Voltage (Referenced to GND) -0.5 to VCC +0.5 V VOUT DC Output Voltage (Referenced to GND) -0.5 to VCC +0.5 V IIN DC Input ...
KK4029B: PinoutSpecifications Symbol Parameter Value Unit VCC DC Supply Voltage (Referenced to GND) -0.5 to +20 V VIN DC Input Voltage (Referenced to GND) -0.5 to VCC +0....
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Symbol |
Parameter |
Value |
Unit |
VCC |
DC Supply Voltage (Referenced to GND) |
-0.5 to +20 |
V |
VIN |
DC Input Voltage (Referenced to GND) |
-0.5 to VCC +0.5 |
V |
VOUT |
DC Output Voltage (Referenced to GND) |
-0.5 to VCC +0.5 |
V |
IIN |
DC Input Current, per Pin |
±10 |
mA |
PD |
Power Dissipation in Still Air, Plastic DIP+ SOIC Package+ |
750 |
mW |
PD |
Power Dissipation per Output Transistor |
100 |
mW |
Tstg |
Storage Temperature |
-65 to +150 |
|
TL |
Lead Temperature, 1 mm from Case for 10 Seconds (Plastic DIP or SOIC Package) |
260 |
The KK4029B consists of a four-stage binary or BCD-decade up/down counter with provisions for look-ahead carry in both counting modes. The inputs consists of a single CLOCK, CARRY IN,(CLOCK ENABLE), BINARY/DECADE, UP/DOWN, PRESET ENABLE, and four individual JAM signals. Q1, Q2, Q3, Q4 and a CARRY OUT signal are provided as outputs.
A high PRESET ENABLE signal allows information on the JAM INPUTS to preset the counter to any state asynchronously with the clock.
low on each JAM line, when the PRESET-ENABLE signal is high, resets the counter to its zero count. The counter is advanced one count at the positive transition of the clock when the CARRY IN and PRESET ENABLE signals are low. Advancement is inhibited when the CARRY IN or PRESET ENABLE signals are high. The CARRY OUT signal is normally high and goes low when the counter reaches its maximum count in the UP mode or the minimum count in the DOWN mode provided the CARRY IN signal is low. The CARRY IN signal in the ENABLE. The CARRY IN terminal must be connected to GND when not in use.
Binary counting is accomplished when the BINARY/DECADE input is high; the counter counts in the decade mode when the BINARY/DECADE input is low. The counter counts up when the UP/DOWN input is high, and down when the UP/DOWN input is low.
Parallel clocking provides synchronous control and hence faster response from all counting outputs. Ripple-clocking allows for longer clock input rise and fall times.Operating Voltage Range: 3.0 to 18 V Maximum input current of 1 A at 18 V over full package-temperature range; 100 nA at 18 V and 25
Noise margin (over full package temperature range):
1.0 V min @ 5.0 V supply
2.0 V min @ 10.0 V supply
2.5 V min @ 15.0 V supply