Specifications Parameter Symbo 5 secs Steady State Unit Drain-Source Voltage VDS -20 V Gate-Source Voltage VGS ±8 Continuous Drain Current (TJ = 150 ) * TA=25 ID -4.8 -3.5 A TA= 85 -3.5 -2.5 Pulsed Drain Current IDM -1...
KI5447DC: Specifications Parameter Symbo 5 secs Steady State Unit Drain-Source Voltage VDS -20 V Gate-Source Voltage VGS ±8 Continuous Drain Current (TJ = 150 ) * ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter |
Symbo |
5 secs |
Steady State |
Unit | |
Drain-Source Voltage |
VDS |
-20 |
V | ||
Gate-Source Voltage |
VGS |
±8 | |||
Continuous Drain Current (TJ = 150 ) * |
TA=25 |
ID |
-4.8 |
-3.5 |
A |
TA= 85 |
-3.5 |
-2.5 | |||
Pulsed Drain Current |
IDM |
-15 | |||
Continuous Source Current * |
IS |
-2.1 |
-1.1 | ||
Maximum Power Dissipation * |
TA=25 |
PD |
2.5 |
1.3 |
W |
TA= 85 |
1.3 |
0.7 | |||
Operating Junction and Storage Temperature Range |
TJ, Tstg |
-55 to 150 |
|||
Soldering Recommendations (Peak Temperature) |
260 |
||||
Parameter |
Symbol |
Typ |
Max |
Uni | |
Maximum Junction-to-Ambient* |
t 5 sec |
RthJA |
43 |
50 |
/W |
Steady-State |
83 |
95 | |||
Maximum Junction-to-Foot (Drain) |
Steady-State |
RthJF |
14 |
20 |