Features: • 11.1Gbps Operation• Differential Input• High Output Voltage: Maximum Amplitude > 2.7 Vpp• X-Point Control Function• Output Amplitude Control Function• Output Bias Control FunctionApplication1. For stable operation;1-1. To prevent a dependence of ...
KGL4115HW-R: Features: • 11.1Gbps Operation• Differential Input• High Output Voltage: Maximum Amplitude > 2.7 Vpp• X-Point Control Function• Output Amplitude Control FunctionR...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
1. For stable operation;
1-1. To prevent a dependence of "X-Point" on the supply voltage VS,
(1) Use an external voltage source of 3.8V for "VB2", or
(2) Control the voltage of "VB1", so that the voltage difference "VB1VB2" is constant.
1-2. To prevent a dependence of "Output amplitude" on the supply voltage VS, Control the voltage of "VC1", so that the voltage difference "VC1VS" is constant.
1-3. To prevent a dependence of "Output bias control voltage" on supply voltage VS, Control the voltage of "VC2", so that the voltage difference "VC2VS" is constant.
2. Power-up/shut-down sequence;
For power-up, supply control voltages (VB1, (VB2), VC1, VC2) at first, then Vs. For shut-down, Vs at first, then control voltages.
Customer does not need to care about the sequence for the control voltages (VB1,(VB2),VC1,VC2).
3. Under "no signal input" condition, the operation may not be stable.
Parameter | Symbol | Min | Max | Unit | Note |
Supply Voltage | VS | -6.5 | 0.3 | V | |
X-Point Control Voltage | VB1 | VS-4.5 (Min. -6.5) |
VS+2.4 (Max. 0.3) |
V | |
Output Amplitude Control Voltage | VC1 | -6.5 | VS+1.2 (Max. 0.3) |
V | |
Output Bias Control Voltage | VC2 | -6.5 | VS+2.4 (Max. 0.3) |
V | |
Operating Temperature at Package Base |
Ts | -10 | 100 | ||
Storage Temperature | Tst | -40 | 125 |