Features: • 50-kHz input range and 0.006% accuracy for sophisticated control.• A wide selection of outputs: relay, transistor, BCD, linear, or communications.• Maximum/Minimum value hold, set value write protection, and more.• Banks with four comparative output values and f...
K3NR: Features: • 50-kHz input range and 0.006% accuracy for sophisticated control.• A wide selection of outputs: relay, transistor, BCD, linear, or communications.• Maximum/Minimum valu...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
• 50-kHz input range and 0.006% accuracy for sophisticated control.
• A wide selection of outputs: relay, transistor, BCD, linear, or communications.
• Maximum/Minimum value hold, set value write protection, and more.
• Banks with four comparative output values and four prescale values.
• Prescale function available, which displays in units of actual physical parameters (length, volume, etc.).
• Set value teaching, linear output range teaching, and prescale teaching are available using actual measured values.
• Displays values in hours, minutes, and seconds in operating mode 6.
• A startup compensation time parameter keeps the measurement operation from sending an unnecessary output for a preset period up to 99.9 s.
• Built-in sensor power supply (12 VDC, 80 mA).
• Compact 1/8 DIN size.
• Conforms to EMC standards, EN61010-1 (IEC61010-1).
• UL/CSA approved.
Supply voltage | 100 to 240 VAC (50/60 Hz); 12 to 24 VDC |
Operating voltage range | 85% to 110% of supply voltage |
Power consumption (see note) | 15 VA max. (max. AC load with all indicators lit) 10 W max. (max. DC load with all indicators lit) |
Sensor power supply | 80 mA at 12 VDC±10% |
Insulation resistance | 20 M min. (at 500 VDC) between external terminal and case. Insulation provided between inputs, outputs, and power supply. |
Dielectric strength | 2,000 VAC for 1 min between external terminal and case. Insulation provided between inputs, outputs, and power supply |
Noise immunity | ±1,500 V on power supply terminals in normal or common mode ±1 s, 100 ns for square-wave noise with 1 ns |
Vibration resistance | Malfunction: 10 to 55 Hz, 0.5-mm for 10 min each in X, Y, and Z directions Destruction: 10 to 55 Hz, 0.75-mm for 2 hrs each in X, Y, and Z directions |
Shock resistance | Malfunction: 98 m/s2 for 3 times each in X, Y, and Z directions Destruction: 294 m/s2 for 3 times each in X, Y, and Z directions |
Ambient temperature | Operating: −10°C to 55°C (with no icing) Storage: −20°C to 65°C (with no icing) |
Ambient humidity | Operating: 25% to 85% (with no condensation) |
EMC | (EMI) EN61326+A1 Industry Emission Enclosure: CISPR 11 Group 1 class A: CISRP16-1/-2 Emission AC Mains: CISPR 11 Group 1 class A: CISRP16-1/-2 (EMS) EN61326+A1 Industry Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (amplitude-modulated, 80 MHz to 1 GHz) (level 3) Immunity Fast Transient Noise: EN61000-4-4: 2 kV (power line) (level 3) Immunity Burst Noise: 1 kV line to line (I/O signal line) Immunity Surge: EN61000-4-5: 1 kV line to line 2 kV line to ground (power line) Immunity Conducted Disturbance EN61000-4-6: 3 V (0.15 to 80 MHz) (level 2) Immunity Voltage Dip/Interrupting EN61000-4-11: 0.5 cycles, 0, 180°, 100% (rated voltage) |
Approved standards | UL508, CSA22.2; Conforms to EN61326+A1, EN61010-1 (IEC61010-1) Conforms to VDE0106/P100 (finger protection) when the terminal cover is mounted. |
Weight | Approx. 400 g |
High-speed, Intelligent Interface Modules with Seven Operating Modes Convert Single or Dual Input Pulses to Display Values K3NR