• Pb-Free available (RoHS compliant)
• Drop in replacement for the MAX4715 and MAX4716
• ON resistance (RON)
- VCC = +4.3V. . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.21
- VCC = +3.0V. . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.24
- VCC = +1.8V. . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.45
• RON flatness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.03
• Single supply operation . . . . . . . . . . . . . +1.1V to +4.5V
• Fast switching action (+3.9V Supply)
-tON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... . 8ns
- tOFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .... 5ns
• ESD HBM rating . . . . . . . . . . . . . . . . . . . . . . . . . .. >4kV
• 1.8V, CMOS logic compatible (+3V supply)
• 5 lead SC70 packaging
V+ to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . -0.3 to 4.7V
Input Voltages
NO, NC, IN (Note 2) . . . . . . . . . . . . . . . . . . . -0.3 to ((V+) + 0.3V)
Output Voltages
COM (Note 2) . . . . . . . . . . . . . . . . . . . . . ... . -0.3 to ((V+) + 0.3V)
Continuous Current NO, NC, or COM . . . . . . . . . . . . . . . ±300mA
Peak Current NO, NC, or COM
(Pulsed 1ms, 10% Duty Cycle, Max) . . . . . . . . . . . . . . . ± 600mA
ESD Rating:
HBM > . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>4kV
MM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>300V
CDM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>1000V