Features: • On-chip Oscillator Compensation Over the Operating Temp Range - ±5ppm over -20 to +70• Day Light Saving Time - Customer Programmable• Separate FOUT pin - 15 Selectable Frequency Outputs• 1 Alarm - Settable to the Second, Minute, Hour, Day of the Week,Day, or Mon...
ISL12021: Features: • On-chip Oscillator Compensation Over the Operating Temp Range - ±5ppm over -20 to +70• Day Light Saving Time - Customer Programmable• Separate FOUT pin - 15 Selectable ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Voltage on VDD, VBAT, SCL, SDA, IRQ, FOUT and LVRST pins
(respect to ground) . . . . . . . . . . . . . . . . . . . . . . . . ... -0.3V to 6.0V
Voltage on X1 and X2 pins
(respect to ground) . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 2.5V
ESD Rating
Human Body Model (Per MIL-STD-883 Method 3014) . . . ...... .>2kV
Machine Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... . .>150V
CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
The ISL12021 device is a low power real time clock with an embedded Temp sensor for oscillator compensation, clock/calendar, power fail, low battery monitor, brown out indicator, single periodic or polled alarms, intelligent battery backup switching and 128 bytes of battery-backed user SRAM.
The oscillator ISL12021 uses an external, low-cost 32.768kHz crystal. The real time clock tracks time with separate registers for hours, minutes, and seconds. The ISL12021 has calendar registers for date, month, year and day of the week. The calendar is accurate through 2099, with automatic leap year correction.
Daylight Savings time adjustment is done automatically, using parameters entered by the user. Power fail and battery monitors offer user-selectable trip levels. A time stamp function records the time and date of switchover from VDD to battery power, and also from battery to VDD power.