Carrier Frequency : | 36 KHz | Transmission Distance : | 14 m |
Viewing Angle : | 45 deg | High Level Pulse Width : | 400 us |
Low Level Pulse Width : | 400 us | Minimum High Level Output Voltage : | 4.5 V |
Output Current : | 1.2 mA | Operating Voltage : | 0 V to 6 V |
Maximum Operating Temperature : | + 85 C | Minimum Operating Temperature : | - 25 C |
Packaging : | Bulk |
The features of IRM-2636A/TR1-11(A) are Photo detector and preamplifier in one package, Internal filter for PCM frequency, Improved shielding against electrical field disturbance, TTL and CMOS compatibility, Output active low, Low power consumption, Improved immunity against ambient light, Suitable burst length 10 pulses/burst, Pb free, The product itself will remain within RoHS compliant version.
The IRM2636A/TR1-11 are miniaturized receivers for infrared remote control systems. PIN diode and preamplifier are assembled on lead frame, the epoxy package is designed as IR filter. The demodulated output signal can directly be decoded by a microprocessor. IRM2636A/TR1-11 is the standard IR remote control receiver series, supporting all major transmission codes.
The IRM-2636A/TR1-11(A) can be used as1. Optical switch, 2. Light detecting portion of remote control, AV instruments such as Audio, TV, VCR, CD, MD, etc., Home appliances such as Air-conditioner, Fan, etc., The other equipments with wireless remote control., CATV set top boxes, Multi-media Equipment.
The absolute maximum ratings (Ta=25) of IRM-2636A/TR1-11(A) are Supply Voltage (Vcc)=0~6 V, Operating Temperature(Topr)=-25 ~ +80, Storage Temperature(Tstg)=-40 ~ +85 , Soldering Temperature(Tsol)=260 (4mm from mold body less than 10 seconds)
Test Method:The specified electro-optical characteristics is satisfied under the following Conditions at the controllable distance. 1.Measurement place A place that is nothing of extreme light reflected in the room. 2.External light Project the light of ordinary white fluorescent lamps which are not high Frequency lamps and must be less then 10 Lux at the module surface. (Ee10Lux) 3.Standard transmitter A transmitter whose output is so adjusted as to Vo=400mVp-p and the output Wave form shown in Fig.-1.According to the measurement method shown in Fig.-2 the standard transmitter is specified. However , the infrared photodiode to be used for the transmitter should be p=940nm,∆=50nm. Also, photodiode is used of PD438B(Vr=5V). 3.Measuring system According to the measuring system shown in Fig.3.