Features: · Floating channel designed for bootstrap operation Fully operational to +600V Tolerant to negative transient voltage dV/dt immune· Gate drive supply range from 10 to 20V (IR2136), 11.5 to 20V (IR21362) or 12 to 20V (IR21363)· Undervoltage lockout for all channels· Over-current shutdown ...
IR21363(J&S): Features: · Floating channel designed for bootstrap operation Fully operational to +600V Tolerant to negative transient voltage dV/dt immune· Gate drive supply range from 10 to 20V (IR2136), 11.5 to...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Symbol |
Definition |
Min. |
Max. |
Units |
Vs |
High Side Floating Supply Voltage |
-0.3 |
625 |
|
VBS |
High Side Floating Offset Voltage |
-0.3 |
25 |
V |
VHO |
High Side Floating Output Voltage |
VS1,2,3 - 0.3 |
VB1,2,3 + 0.3 | |
VCC |
Low Side and Logic Fixed Supply Voltage |
-0.3 |
25 | |
VSS |
Logic Ground |
VCC - 25 |
VCC + 0.3 | |
VLO1,2,3 |
Low Side Output Voltage |
- 0.3 |
VCC + 0.3 | |
VIN |
Logic input voltage (HIN, LIN, ITRIP, SD & FLT-CLR) |
VSS - 0.3 |
(VSS + 15) or (VCC + 0.3) whichever is lower | |
VFLT |
FAULT Output Voltage |
VSS - 0.3 |
VCC + 0.3 |
|
dVS/dt |
Allowable Offset Supply Voltage Transient |
- |
50 |
V/ns |
PD |
Package Power Dissipation @ TA +25°C (28 Lead DIP) |
- |
1.5 |
|
(28 Lead SOIC) |
- |
1.6 |
W | |
(44 Lead PLCC) |
- |
2.0 |
||
RthJA |
Thermal Resistance, Junction to Ambient (28 Lead PDIP) |
- |
83 |
|
(28 Lead SOIC) |
- |
78 |
°C/W | |
(44 Lead PLCC) |
- |
63 | ||
TJ |
Junction Temperature |
- |
150 |
|
TS |
Storage Temperature |
-55 |
150 |
°C |
TL |
Lead Temperature (Soldering, 10 seconds) |
- |
300 |
The IR2136/IR21362/IR21363(J&S) are high votage, high speed power MOSFET and IGBT drivers with three in-dependent high and low side referenced output channels for 3-phase applications. Proprietary HVIC technology enables ruggedized monolithic construc-tion. Logic inputs are compatible with CMOS or LSTTL outputs, down to 3.3V logic. A current trip function which terminates all six outputs can be de-rived from an external current sense resistor. An enable function is available to terminate all six outputs simul-taneously. An open-drain FAULT signal is provided to indicate that an overcurrent or undervoltage shutdown has occurred. Overcurrent fault conditions are cleared