Product : | Ultra Fast Recovery Rectifiers | Configuration : | Single |
Reverse Voltage : | 200 V | Forward Voltage Drop : | 1 V |
Recovery Time : | 50 ns | Forward Continuous Current : | 5 A |
Max Surge Current : | 200 A | Reverse Current IR : | 10 uA |
Mounting Style : | Through Hole | Package / Case : | DO-201AD |
Packaging : | Reel |
SYMBOLS | HER 501G |
HER 502G |
HER 503G |
HER 504G |
HER 505G |
HER 506G |
HER 507G |
HER 508G |
UNIT | |
Maximum Repetitive Peak Reverse Voltage | VRRM | 50 | 100 | 200 | 300 | 400 | 600 | 800 | 1000 | Volts |
Maximum RMS Voltage | VRMS | 35 | 70 | 140 | 210 | 280 | 420 | 560 | 700 | Volts |
Maximum DC Blocking Voltage | VDC | 50 | 100 | 200 | 300 | 400 | 600 | 800 | 1000 | Volts |
Maximum Average Forward Rectified Current, 0.375" (9.5mm) lead length at TA = 50 OC |
I(AV) | 5.0 | Amps | |||||||
Peak Forward Surge Current 8.3mS single half sine wave superimposed on rated load (JEDEC method) |
IFSM | 200 | 150 | Amps | ||||||
Maximum Instantaneous Forward Voltage @ 5.0A | VF | 1.0 | 1.3 | 1.5 | 1.7 | Volts | ||||
Maximum DC Reverse Current at Rated TA = 25 OC DC Blocking Voltage per element TA = 125 OC |
IR | 10 500 |
A | |||||||
Maximum Full Load Reverse Current, Full Cycle average 0.375" (9.5mm) lead length at TL = 55 OC |
IR(AV) | 150 | A | |||||||
Maximum Reverse Recovery Time Test conditions IF = 0.5A, IR = 1.0A, IRR = 0.25A |
trr | 50 | 70 | nS | ||||||
Typical Junction Capacitance (Measured at 1.0MHz and applied reverse voltage of 4.0V) |
CJ | 70 | 50 | pF | ||||||
Typical Thermal Resistance (Note 1) | RJA | 20 | OC/W | |||||||
Operating Junction Temperature | TJ | (-55 to +150) | OC | |||||||
Storage Temperature Rang | TSTG | (-55 to +150) | OC |