DescriptionThe features of HEMP100G are as follows: (1)accommodate universal AC sources; (2)green power design/meet energy star(CEC) lvevl IV; (3meet medical standards EN60601-1/UL60601-1; (4)desktop IEC320-2P AC receptacle; (5)EMI EN55011/ FCC CLASS B. The following is about the absolute maximum...
HEMP100G: DescriptionThe features of HEMP100G are as follows: (1)accommodate universal AC sources; (2)green power design/meet energy star(CEC) lvevl IV; (3meet medical standards EN60601-1/UL60601-1; (4)deskto...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The features of HEMP100G are as follows: (1)accommodate universal AC sources; (2)green power design/meet energy star(CEC) lvevl IV; (3meet medical standards EN60601-1/UL60601-1; (4)desktop IEC320-2P AC receptacle; (5)EMI EN55011/ FCC CLASS B.
The following is about the absolute maximum ratings of HEMP100G: (1)Inrush Current: 7.2Arms @230Vac 50Hz; (2)Input Voltage: Typ. 90-264Vac; (3)Input Current: 0.976A@115Vac/0.496A@230Vac; (4)Output Wattage: 100 Watts; (5)Line Regulation: 0.3% typical; (6)Load Regulation: ± 2 % typical.
The electrical characteristics of the HEMP100G are: (1)Efficiency: 88-90% typical; (2)Switching Frequency: 40-65K Hz; (3)Circuit Topology: Fixed Flyback circuit; (4)Transient Response: Output voltage returns in less than 1mS following a 25% load change; (5)Safety Standard: Meet Medical standards UL60601-1 /EN60601-1Class I or II; (6)Operating Temperature: 0 to +25/35/40°C without derating; (7)Storage Temperature: -20 to +85°C.