DescriptionThe features of HEMG75-300240-7 are as follows: (1)accommodate universal AC sources; (2)desktop IEC320-3P AC receptacle; (3)meet medical standards EN60601-/UL60601-1; (4)green power design/ meet energy star(CEC) LVEVL IV; (5)EMI meet EN 55011/ FCC class B; (6)CE marking compliance. The...
HEMG75-300240-7: DescriptionThe features of HEMG75-300240-7 are as follows: (1)accommodate universal AC sources; (2)desktop IEC320-3P AC receptacle; (3)meet medical standards EN60601-/UL60601-1; (4)green power desig...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The features of HEMG75-300240-7 are as follows: (1)accommodate universal AC sources; (2)desktop IEC320-3P AC receptacle; (3)meet medical standards EN60601-/UL60601-1; (4)green power design/ meet energy star(CEC) LVEVL IV; (5)EMI meet EN 55011/ FCC class B; (6)CE marking compliance.
The following is about the absolute maximum ratings of HEMG75-300240-7: (1)Inrush Current: Typ. 57.6A @ 230Vac; (2)Input Voltage: Typ. 90-264Vac; (3)Input Current: Typ. 1.2A @ 115Vac, 0.59A @ 230Vac; (4)Output Wattage: Typ. 70 Watts; (5)Line Regulation: Typ. 1%; (6)Load Regulation: ± 3 % typical.
The electrical characteristics of the HEMG75-300240-7 are: (1)Efficiency: 84-85% typical; (2)Switching Frequency: Typ. 60KHz; (3)Circuit Topology: Fixed Frequency Flyback circuit; (4)Transient Response: Output voltage returns in less than 1mS following a 25% load change; (5)Safety Standard: Medical standards IEC60601-1/EN60601-1/ UL60601-1, Class I for DT7; (6)Operating Temperature: 0 to +25/35/40°C without derating; (7)Storage Temperature: -20 to +85°C.