Features: • Product primarily designed for circuits requiring large energy momentarily like those for the uninterruptible power supply (UPS) and X-ray power supply • Capacitance improved by 40%, comparison with the HCGF6 model (smallest model)Specifications Item Specifica...
HCGW: Features: • Product primarily designed for circuits requiring large energy momentarily like those for the uninterruptible power supply (UPS) and X-ray power supply • Capacitance improved...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
• Product primarily designed for circuits requiring large energy momentarily like those for the uninterruptible power supply (UPS) and X-ray power supply
• Capacitance improved by 40%, comparison with the HCGF6 model (smallest model)
Item |
Specifications |
||||||||
Temperature range |
10 ~ +85 | ||||||||
Rated current |
350 ~ 500V.DC | ||||||||
Capacitance tolerance |
±20%(20,120Hz) | ||||||||
Leakage current |
This current must be less than or equal to a smaller value of I=0.01CV and 7mA (20, 5 minutes). (I: Leakage current, C: F), V: Rated voltage (VDC) |
||||||||
Dissipation factor |
Must be less than or equal to 0.70 (20, 120Hz) | ||||||||
Withstand voltage |
No abnormality must be found when 2,000 VDC is applied between the terminal block and the mount fixture (to be attached to the case which has been coated doubly with an armored sleeve). |
||||||||
Load at high temperature |
The requirements shown in the following table must be met under conditions that allowable
|
||||||||
No load at high temperature |
The requirements of the above table (shown in the column"Load at High Temperature") must be met under conditions that the capacitor is left at 85 for 500 hours with no voltage applied, the temperature is lowered again to 20 and preprocessing for tests (4.4 in JIS C5102) is performed. |
||||||||
Related standard |
JIS C 5101-4 |