Features: • Delivers up to 50 W in half brick• No minimum load required• Low profile of only 0.50 inch• 2.5V, 3.3V, 5V, 12V, 15V or 24V output models• Input operating range 9-18V• -40 to +100 ambient operation• On/Off pin and remote sense• Output adj...
HB50-12: Features: • Delivers up to 50 W in half brick• No minimum load required• Low profile of only 0.50 inch• 2.5V, 3.3V, 5V, 12V, 15V or 24V output models• Input operating r...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
• Delivers up to 50 W in half brick
• No minimum load required
• Low profile of only 0.50 inch
• 2.5V, 3.3V, 5V, 12V, 15V or 24V output models
• Input operating range 9-18V
• -40 to +100 ambient operation
• On/Off pin and remote sense
• Output adjustment +10% and 10% range
• 1500V, 10M input-to-output isolation
• Meets Basic Insulation requirements of EN60950
• UL 1950 recognized, TUV EN60950 and CSA C22.2 No. 60950-00 Certified (pending)
• Meets conducted limits of FCC Class B and CEI IEC61204-3 Class B with external filter
• MTBF of 1,000,000 hours @ 50(Bellcore)
PARAMETER |
NOTES |
MIN |
TYP |
MAX |
UNIT |
Input voltage |
0 |
24 |
V | ||
Operating case temperature |
-40 |
100 |
|||
Storage temperature |
-40 |
105 |
|||
Humidity |
95 |
% | |||
Operating input voltage range |
9 |
24 |
V | ||
Turn on voltage threshold |
8.8 |
V | |||
Turn off voltage threshold |
8.2 |
V | |||
Off converter input current 12Vin |
5 |
mA |
The HB50-12 Series of low cost half brick DC/DC converters are comparable to existing half-bricks. They are targeted specifically at the telecommunication, industrial electronics, mobile telecommunication and distributed power markets. With a wide input voltage range of 9-18V they are available with output voltage of either 2.5, 3.3, 5, 12, 15 or 24 Volts. All HB50-12 Series of models feature an input filter, input undervoltage lockout, output overvoltage and overtemperature protection, output current limiting and short circuit protection. The unique open-frame construction with aluminum heat spreader design achieves efficient heat transfer with no hot spots.