Features: This LSI includes an interrupt controller, which has the following features.• Priorities settable with IPRAn interrupt priority register (IPR) is provided for setting mask levels for interrupts. Three mask levels can be set for each module for all interrupts except an NMI and addre...
H8/38799: Features: This LSI includes an interrupt controller, which has the following features.• Priorities settable with IPRAn interrupt priority register (IPR) is provided for setting mask levels for...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
This LSI includes an interrupt controller, which has the following features.
• Priorities settable with IPR
An interrupt priority register (IPR) is provided for setting mask levels for interrupts. Three mask levels can be set for each module for all interrupts except an NMI and address break.
• Interrupts can be enabled or disabled in three levels by the INTM1 and INTM0 bits in the interrupt mask register (INTM).
• Fourteen external interrupts
NMI is the highest-priority interrupt, and is accepted at all times. Rising or falling edge sensing can be selected for NMI. Rising or falling edge sensing can be selected for IRQ0,IRQ1, IRQ3, IRQ4, and WKP0 to WKP7. Rising, falling, or both edge sensing can be selected for IRQAEC.
Item | Symbol | Value | Unit | Note | |
Power supply voltage | VCC | 0.3 to +4.3 | V | *1 | |
Analog power supply voltage | AVCC | 0.3 to +4.3 | V | ||
Input voltage | Other than port B |
Vin | 0.3 to VCC +0.3 | V | |
Port B | 0.3 to AVCC +0.3 | V | |||
Operating temperature | Topr | 20 to +75 (general specifications)*2 |
|||
40 to +85 (wide temperature range specifications)*2 |
|||||
Storage temperature | Tstg | 55 to +125 |
Notes: 1. Permanent damage may occur to the chip if absolute maximum ratings are exceeded. Normal operation should be under the conditions specified in Electrical Characteristics. Exceeding these values can result in incorrect operation and reduced reliability.
2. When the operating voltage (Vcc) for reading the flash memory is from 2.7 V to 3.6 V, the operating temperature (Ta) for programming/erasing ranges from 20 to +75°C.When the operating voltage (Vcc) for reading the flash memory is from 1.8 V to 3.6 V, the operating temperature (Ta) for programming/erasing ranges from 20 to +50°C.