Features: ·Plastic package has Underwriters Laboratory Flammability Classification 94V-0·For surface mount applications·Low profile package·Built-in strain relief, ideal for automated placement·Fast switching for high efficiency·Easy pick and place·Glass passivated chip junction·High temperature s...
GR3M: Features: ·Plastic package has Underwriters Laboratory Flammability Classification 94V-0·For surface mount applications·Low profile package·Built-in strain relief, ideal for automated placement·Fast...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Symbols | GR3A | GR3B | GR3D | GR3G | GR3J | GR3K | GR3M | Units | |
Maximum repetitive peak reverse voltage | VRRM | 50 | 100 | 200 | 400 | 600 | 800 | 1000 | Volts |
Maximum RMS voltage | VRMS | 35 | 70 | 140 | 280 | 420 | 560 | 700 | Volts |
Maximum DC blocking voltage | VDC | 50 | 100 | 200 | 400 | 600 | 800 | 1000 | Volts |
Maximum Average Forward Current Ta = 75 °C | IF(AV) | 3.0 | Amps | ||||||
Peak Forward Surge Current, 8.3ms Single half sine wave superimposed on rated load (JEDEC Method) |
IFSM | 100.0 | AAmps | ||||||
Maximum instantaneous forward voltage at 1.0A | VF | 1.30 | Volts | ||||||
Maximum DC reverse current TA=25 at rated DC blocking voltage TA=125 |
IR | 10.0 250.0 |
A | ||||||
Maximum reverse recovery time (Note 1) | Trr | 150 | 250 | 500 | nS | ||||
Typical junction capacitance (Note 2) | CJ | 60.0 | F | ||||||
Typical thermal resistance (Note 3) | RJA RJL |
15.0 50.0 |
/W | ||||||
Storage Temperature Range | TSTG | - 65 to + 150 |