Description
Features:
Specifications
Description
The GDW14 is a very good product. If you want to use it you must learn about it rightly. The GDW14 can be described as followings. GDW14 VCXOs are packaged in an industry-standard, 14 pin dualin-line package. Typical phase jitter for GDW series VCXOs is 2.35ps.Output is LVDS. Applications include phase lock loop, SONET/ATM,
set-top boxes, MPEG , audio/video modulation, video game consolesand HDTV.
The GDW14 has five features. Please pay attention to them. The first feature of it is that the frequency ranges from 38MHz to 640MHz. The second feature of it is LVDS output. The third feature of it is supply voltage, which is 3.3 VDC. The fourth feature of it is phase jitter 0.4ps typical. The fifth feature of it is that pull range from ±30ppm to ±150ppm.
The specification of the GDW14 can make you clear of the GDW14, I am very glad to show you the specification of the GDW14. The first specification of the GDW14 is frequency range, which ranges from 750kHz to 800.0MHz. The second specification of the GDW14 is supply voltage, which is 3.3 VDC ±5%. The third specification of the GDW14 is output logic, which is LVDS. The fourth specification of the GDW14 is RMS period jitter, which is 4.3ps typical. The fifth specification of the GDW14 is peak to peak jitter, which is 27.0ps typical. The sixth specification of the GDW14 is phase jitter, which is 2.35ps typical. The seventh specification of the GDW14 is initial frequency accuracy, which is tune to the nominal frequencywith Vc= 1.65 ±0.2VDC. The eighth specification of the GDW14 is output voltage HIGH (1), which is 1.4 volts typical. The ninth specification of the GDW14 is output voltage LOW (0), which is 1.1 Volts typical. The tenth specification of the GDW14 is pulling range, which range from ±30ppm to ±150ppm. The eleventh specification of the GDW14 is control voltage range, which is 1.65 ±1.35 volts. The twelfth specification of the GDW14 is temperature stability, which is See table. The thirteenth specification of the GDW14 is output load, which is 50 into vdd or thevenin equiv. The fourteenth specification of the GDW14 is duty cycle, which is 50% ±5%. The fifteenth specification of the GDW14 is start-up time, which is 10ms maximum, and 5ms typical. The sixteenth specification of the GDW14 is current consumption, which is 55mA typical, and 60mA maximum. The seventeenth specification of the GDW14 is static discharge protection, which is 2kV maximum. The eighteenth specification of the GDW14 is storage Temperature, which range from -55° to +150°C. The nineteenth specification of the GDW14 is ageing, which is ±2ppm per year maximum.
At present there is not too much information about this model. If you are willing to find more about the GDW14, please pay attention to our web! We will promptly update the relevant information.