Specifications Parameter Symbol Test Conditions Min Max Units Drain Supply Voltage VDD -3V < VGS < +0V 12 V Gate Supply Voltage VGG 0V < VDD < +8V -3 V Operating Current IOP For VDS > 2V 1.8 A Gate Current IG Forward or reverse c...
FRD3500X230: Specifications Parameter Symbol Test Conditions Min Max Units Drain Supply Voltage VDD -3V < VGS < +0V 12 V Gate Supply Voltage VGG 0V < VDD < +8V ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter |
Symbol |
Test Conditions |
Min |
Max |
Units |
Drain Supply Voltage | VDD | -3V < VGS < +0V | 12 | V | |
Gate Supply Voltage | VGG | 0V < VDD < +8V | -3 | V | |
Operating Current | IOP | For VDS > 2V | 1.8 | A | |
Gate Current | IG | Forward or reverse current | +60/-15 | mA | |
RF Input Power2 | PIN | Under any acceptable bias state | 500 | mW | |
Channel Operating Temperature | TCH | Under any acceptable bias state | 175 | ºC | |
Storage Temperature | TSTG | Non-Operating Storage | -40 | 150 | ºC |
Total Power Dissipation | PTOT | Ambient temperature to 85ºC | 12 | W | |
Gain Compression | Comp. | Under any bias conditions | 5 | dB | |
Simultaneous Combination of Limits3 | 2 or more Max. Limits | 80 | % |