Specifications Nominal Frequency 1.000MHz to 106.250MHz The specified reference or "center" frequency of the oscillator. Typically specified in megahertz (MHz)or kilohertz (kHz). Frequency Tolerance/Stability (Inclusive of all conditions: Calibration Tolerance a...
EP26: Specifications Nominal Frequency 1.000MHz to 106.250MHz The specified reference or "center" frequency of the oscillator. Typically specified in megahertz (MHz)or kilohertz (k...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Nominal Frequency | 1.000MHz to 106.250MHz | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Frequency Tolerance/Stability | (Inclusive of all conditions: Calibration Tolerance at 25°C, Frequency Stability over the Operating Temperature Range, Supply Voltage Change, Output Load Change, First Year Aging at 25°C, Shock, and Vibration.) ±100ppm Maximum (Standard) ±50ppm Maximum | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Operating Temperature Range | -20°C to +70°C (Standard) -40°C to +85°C | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Supply Voltage (VDD) | 3.3VDC ±0.3VDC | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Input Current | 28mA Maximum (Unloaded) | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
Disable Current (Tri-State Option) | 16mA Maximum (Pin 1 = Ground) | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
Standby Current (Power Down Option) | 20µA Maximum (Pin 1 = Ground) | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Output Voltage Logic High (VOH) | VDD-0.4VDC Minimum (IOH=-8mA) | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Output Voltage Logic Low (VOL) | 0.4VDC Maximum (IOL=+8mA) | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Duty Cycle | Measured at 50% of waveform. 50 ±10(%) (Standard) | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Rise Time/Fall Time | Measured from 20% to 80% of waveform. 4nSec Maximum | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Load Drive Capability | 30pF HCMOS Load Maximum from 1.000MHz to 50.000MHz 15pF HCMOS Load Maximum from 50.001MHz to 106.250MHz | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Aging (at 25°C) | ±5ppm/year Maximum | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Storage Temperature | -55°C to +125°C | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
Output Control Function | Tri-State Enable High or Power Down | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
Input Voltage | 70% of VDD or greater or No Connection to enable output. 20% of VDD or less to disable output (High Impedance State for Tri-State. Logic Low for Power Down). | ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
Jitter |
| ||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> | |||||
640){this.height=this.height*640/this.width;this.width=640;}' border="0" alt=" Connection Diagram"> Start Up Time | 10mSec Maximum | ||||