Features: *Single 5V supply*High common-mode voltage range*Each channel individually strobed*Independent response time control*Uncommitted collector or active pull-up option*TTL compatible output*Optional 130X termination resistors*Direct replacement for 9615SpecificationsSupply Voltage, VCC (Note...
DS75115: Features: *Single 5V supply*High common-mode voltage range*Each channel individually strobed*Independent response time control*Uncommitted collector or active pull-up option*TTL compatible output*Op...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Supply Voltage, VCC (Note 1) 7V
Input Voltage at A, B and RT Inputs ±25V
Input Voltage at Strobe Input 5.5V
Off-State Voltage Applied to Open-Collector Outputs 14V
Maximum Power Dissipation* at 25
Cavity Package 1433 mW
Molded Package 1362 mW
Operating Free-Air Temperature Range
DS9615M ±55 to a125
DS57115 0 to ±70
Storage Temperature Range ±65 to ±150
Lead Temperature
(1/16 inch from case for 4 seconds) 260
The DS75115/DS9615 is a dual differential line receiver designed to sense differential signals from data transmission lines. Designed for operation over military and commercial temperature ranges, the DS75115/DS9615 can typically receive g500 mV differential data with g15V common-mode noise. Outputs are open-collector and give TTL compatible signals which are a function of the polarity of the differential input signal. Active output pull-ups are also available, offering the option of an active TTL pull-up through an external connection.
Response time may be controlled with the use of an external capacitor. Each channel may be independently controlled and optional input termination resistors are also available.