Features: · ±3-A Maximum Output Current· Low Supply Voltage Operation: 2.8 V to 5.5 V· High Efficiency Generates Less Heat· Over-Current and Thermal Protection· Fault Indicators for Over-Current, Thermal and Under-Voltage Conditions· Two Selectable Switching Frequencies· Internal or External Clock...
DRV591: Features: · ±3-A Maximum Output Current· Low Supply Voltage Operation: 2.8 V to 5.5 V· High Efficiency Generates Less Heat· Over-Current and Thermal Protection· Fault Indicators for Over-Current, Th...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
DRV591 |
UNIT |
|
Supply voltage, AVDD, PVDD | 0.3 to 5.5 |
V |
Input voltage, VI | 0.3 to VDD + 0.3V |
V |
Output current, IO (FAULT0, FAULT1) | 1 |
mA |
Continuous total power dissipation | See Dissipation Rating Table |
|
Operating free-air temperature range, TA | 40 to 85 |
°C |
Operating junction temperature range, TJ | 40 to 150 |
°C |
Storage temperature range, Tstg | 65 to 165 |
°C |
The DRV591 is a high-efficiency, high-current power amplifier ideal for driving a wide variety of thermoelectric cooler elements in systems powered from 2.8 V to 5.5 V. PWM operation and low output stage on-resistance significantly decrease power dissipation in the amplifier.
The DRV591 is internally protected against thermal and current overloads. Logic-level fault indicators signal when the junction temperature has reached approximately 130°C to allow for system-level shutdown before the amplifier's internal thermal shutdown circuitry activates. The fault indicators also signal when an over-current event has occurred. If the over-current circuitry is tripped, the DRV591 automatically resets (see application information section for more details).
The PWM switching frequency may be set to 500 kHz or 100 kHz depending on system requirements. To eliminate external components, the gain is fixed at approximately 2.3 V/V.