Features: Position sensitivity to ± 5 mV/g, typical Offset Warm-up drift < ± 50 mV, typical Temperature Compensated over 0°C to +50°C Available in Gage and Differential Pressure Ranges Long Term Stability < ± 100 V, typical Combined Linearity and Hysteresis Error < ± 0.25 % Span Applicati...
DCXL20DN: Features: Position sensitivity to ± 5 mV/g, typical Offset Warm-up drift < ± 50 mV, typical Temperature Compensated over 0°C to +50°C Available in Gage and Differential Pressure Ranges Long Term ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Position sensitivity to
± 5 mV/g, typical
Offset Warm-up drift
< ± 50 mV, typical
Temperature
Compensated over
0°C to +50°C
Available in Gage and
Differential Pressure
Ranges
Long Term Stability
< ± 100 V, typical
Combined Linearity and
Hysteresis Error
< ± 0.25 % Span
Min. | Typ. | Max. | Units | |
Excitation Voltage Common Mode Voltage, % Excitation Span*except DCXL01DN Span*DCXL01DN Null* Offset Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])** except DCXL01DN Offset Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])** DCXL01DN Span Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])** Linearity, Hysteresis Error*** Operating Temperature Storage Temperature Offset Warm-up Shift****except DCXL01DN Offset Warm-up Shift****DCXL01DN Offset Position Sensitivity (±1g) except DCXL01DN, DCXL05DN and DCXL10DN Offset Position Sensitivity (±1g) DCXL01DN Offset Position Sensitivity (±1g) DCXL05DN, DCXL10DN Offset Long Term Stability (1 year) except DCXL01DN Offset Long Term Stability (1 year) DCXL01DN |
3.0 -- 19 9.0 - 500 -150 - 250 -200 -- -25 -40 -- -- -- -- -- -- -- |
12.0 50 20.0 10.0 0 -- 0 0 0.05 ± 50 ± 100 ± 5 ± 50 ± 10 ± 100 ± 200 |
16.0 -- 21.0 11.0 +500 +150 +250 +200 0.25 +85 +125 -- -- -- -- -- -- -- |
Vdc % mV mV V V V V %Span °C C C V V V V V V V |
The DCXL line of ultra low pressure sensors is based upon ,SURSENSE , a proprietary technology, which reduces all output offset or common mode errors.
These DCXL sensors use a silicon micromachined sensing element which features a unique stress concentration enhanced structure to provide a highly stable linear output that is proportional to applied pressure. Output offset errors due to changes in temperature, warm-up, long term stability
and position sensitivity have all been significantly reduced when compared to conventional sensors.
The DCXL Series sensors provide a precision calibrated ratiometric ,millivolt output using the enhanced stability of SURSENSE technology. Each sensor features calibrated offset, full scale span and thermal error calibration to ensure the highest possible accuracy for flow pressure measurement. These highly stable sensors feature an industry standard ported package with improved stress isolation for printed circuit board
mount applications.